USBCAN_ERR_MAXMODULES
Value: 0x02
Description:
An application has tried to open more than 10 USB-
CANmoduls. The standard version of the USBCAN32.DLL
only supports up to 10 USB-CANmoduls at the same time. This
error also appears if several applications try to access more than
10 USB-CANmoduls. For example, application 1 has opened 5
modules, application 2 has opened 5 modules and application 3
wants to open a module. Application 3 receives this error
message.
USBCAN_ERR_HWINUSE
Value: 0x03
Description:
An application tries to initialize a USB-CANmodul with the
device number x. If this module has already been initialized by
its own or by another application, this error message is returned.
USBCAN_ERR_ILLVERSION
Value: 0x04
Description:
This error message returns if the firmware version of the USB-
CANmodul is not compatible to the software version of the
USBCAN32.DLL. In this case, install the USB-CAN driver
again.