8. Installing CIPHER 1022R
This section contains a step by step procedures as well as
the expected results (LEDs and buzzer) for installing CIPHER
1022R into your systems. Some of the steps will require you
to do some configurations. Please follow these steps and
check all expected results in detail.
1. Connect D-TYPE 25 pin connector to the communication
port of the computer / terminal. Please check pin
assignments before making the connection.
2. Provide power to CIPHER 1022R. CIPHER 1022R will
activate a long beep and the red LED will be lighted for
about 1 second to indicate a successful power on.
∗
Note :
If any of the above mismatched, turn off the power
immediately and check if any incorrect or improper
connections then repeat the procedures above.
3. Enter configuration mode by reading the "ENTER SETUP"
label. CIPHER 1022R will should activate a L-H-L-H-L-H
beep.
4. Read the "DEFAULT" label to choose the default settings.
CIPHER 1022R should activate a L-H beep.
5. Select the appropriate baud rate, parity, and data bits.
6. Read "UPDATE" label to update settings and exit from
configuration mode.
7. Enter configuration mode by reading the "ENTER SETUP"
label.
8. Enter communication program if necessary.
9. Read the "LIST" label.
10.The system settings will be shown on the screen. CIPHER
1022R should activate a L-H beep.
∗
Note :
If you got a broken display or the PC kept beeping, it
might be the problem of incorrect baud rate, parity, data bits,
or the inter-character delay is not long enough. Correct the
settings now.
11.Read the "UPDATE" label to exit from the configuration
mode. CIPHER 1022R will again activate a L-H-L-H-L-H
beep, and restart normal operation.
12.Modify system settings to meet your application
requirements.