![Syntech Information 1022K User Manual Download Page 14](http://html1.mh-extra.com/html/syntech-information/1022k/1022k_user-manual_1421239014.webp)
CIPHER 1022 User Manual
- 10 -
5. Visual & Audio Indicator
CIPHER 1022 provides LEDs and a BUZZER which work
synchronously to signify various status (unless the buzzer is
disabled).
•
Power On
: The buzzer is activated and the red LED is
lighted for about 1 second to indicate success power-on.
•
Successful Normal Scan
: The buzzer and the red LED
are activated for a short period to indicate successful
reading. The tone and duration can be configurable.
•
Successful Concatenation Scan
: If a label with
embedded concatenation code was decoded, a beep and
the red LED with half the normal duration will be activated.
•
Configuration Mode Entry and Exit
: A low pitch beep
followed by a high pitch beep and repeated for 2 more
times. The red LED is lighted when the buzzer beeps. The
green LED will be lighted when CIPHER 1022 is in
configuration mode.
•
Successful Normal Configuration Scan
: A low pitch
beep followed by a high one. The red LED is lighted when
the buzzer beeps.
•
Value Label pending
: A short beep to indicate that a
value label must be scanned to complete the configuration.
The red LED is lighted when the buzzer beeps.
•
Configuration Error
: Several short beeps to indicate that
some other setting label in stead of a value label is
scanned. The red LED is lighted when the buzzer beeps.