4.  Programmable Features Specific to 1022R 

The  section  describes  the  various  RS-232  transmission 
settings which apply to CIPHER 1022R only. 

4.1  TRANSMISSION MODE 

The option is to select the way CIPHER 1022R transmits data 
upon successful decoding. The supported transmission mode 
and their interpretations are listed below. 

 

FULL  DUPLEX  : 

The  decoded  data  is  transmitted  to  the 

female  D-type  25  pin  connector.  There  is  no  RTS/CTS 
handshake involved. 

 

HALF  DUPLEX  : 

The decoded data is transmitted to both 

the male and female D-type 25 pin connectors. There is no 
RTS/CTS handshake involved. 

 

SCANNER  READY  : 

CIPHER  1022R  will  activate  the  RTS 

signal  upon  powered  on,  and  will  transmit  data  upon 
receiving activated CTS signals. 

 

DATA READY : 

CIPHER 1022R will activate the RTS signal 

to  indicate  a  successful  decoding  and  will  transmit  data 
upon receiving activated CTS signals. 

 

INVERTED  DATA  READY  : 

The  same  as  DATA  READY 

mode  except  the  RTS  logic  is  reversed  (deactivate  RTS 
signal upon successful decoding). 

4.2  Baud Rate / Parity / Data Bits Setting 

The  selectable  values  of  the  baud  rate,  parity,  and  data  bits 
are listed below. The stop bits is fixed to 2 for 1022R. 

 

BAUD RATE : 

38400 / 19200 / 9600 / 4800 / 2400 / 1200 / 

600 / 300 

 

PARITY : 

NO PARITY / EVEN PARITY / ODD PARITY 

 

DATA BITS : 

7 / 8 

Summary of Contents for 1022K

Page 1: ...s Manual CIPHER 1022 SERIES Document Number 1022 52 Ver 1 520 Release Date Apr 22 1996 1996 SYNTECH INFORMATION Co Ltd All rights reserved CipherLab is a registered trademark of SYNTECH INFORMATION Co...

Page 2: ...o radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception wh...

Page 3: ...ata Output 4 2 4 1 Code ID 4 2 4 2 Code Length 6 2 4 3 Prefix and Postfix 6 2 4 4 Trailer Delimiter 6 3 Programmable Features Specific to 1022K 7 3 1 Computer Keyboard Type 7 3 2 Language Support 7 3...

Page 4: ...guration Mode 16 9 2 List Setting 16 9 3 Default Setting 16 9 4 Change Settings 16 9 5 Exit From Configuration Mode 17 10 Kbd Wedge Map Table 18 11 SYSTEM DEFAULT SETTINGS 19 11 1 1022K Default Settin...

Page 5: ...s the decoded data to the computer through RS 232 interface Besides the basic functions the 1022 also provides various features to accommodate versatile environments and application requirements These...

Page 6: ...s from 0 to 250 mili seconds can be selected to match various computer response time Unfortunately efforts must be taken to try out the shortest delay time that still works properly 2 3 Symbology Sett...

Page 7: ...ned to be the actual code length sent excludes Code ID and trailer delimiter Labels with length exceeds these limits will be rejected Make sure that the minimum length setting is no greater than the m...

Page 8: ...s for another symbol to be concatenated If other symbols with embedded concatenation code were decoded again these codes will also be transmitted without Code ID prefix and delimiter When a valid code...

Page 9: ...ddon 5 A EAN13 Addon 5 G Matrix 25 B EAN8 No addon H Code 25 B EAN8 Addon 2 I Interleave 25 B EAN8 Addon 5 K Code 128 N Codabar L Code 93 Code ID Set 3 A UPCA No addon C UPCE No addon A UPCA Addon 2 C...

Page 10: ...es sent are the ASCII code that programmed For 1022K please refer to the bd Wedge Map Table When 1022K is emulating PCAT PS55 PS2 30 or Memorex Telex keystrokes can be sent without the Kbd scan code r...

Page 11: ...Elles IBM PS 55 Macintosh ADB Macintosh RJ11 DEC VT series ADDS 1010 Memorex Telex Compatible with most of the IBM Terminals NEC N5200 NEC PC 9800 Note The Default label will not change the keyboard...

Page 12: ...PHER 1022K to know the status of the capital lock of the keyboard to send the correct case when transmitting data Wrong setting of this option will make upper case letters become lower case letters an...

Page 13: ...male D type 25 pin connectors There is no RTS CTS handshake involved SCANNER READY CIPHER 1022R will activate the RTS signal upon powered on and will transmit data upon receiving activated CTS signals...

Page 14: ...d the red LED with half the normal duration will be activated Configuration Mode Entry and Exit A low pitch beep followed by a high pitch beep and repeated for 2 more times The red LED is lighted when...

Page 15: ...boot up normally except keyboard error this might be resulted from mismatched computer keyboard type This will be discussed later Note If any of the above mismatched turn off the PC immediately and ch...

Page 16: ...eyboard type language or the inter character delay is not long enough Correct the settings now 15 Read the UPDATE label to exit from the configuration mode CIPHER 1022K will again activate a L H L H L...

Page 17: ...er conductor is positive and the outer conductor is negative ground 7 2 Pin Assignments of RS 232 connector CIPHER 1022R could be equipped with one of two kinds of connectors as it is shipped to you T...

Page 18: ...PIN 7 GND Ground PIN 8 connects to pin 8 of male connector PIN 20 connects to pin 20 of male connector PIN 25 Vcc 5V Power Input 7 2 2 Single Connector Type The connector is equipped with a D Type 25...

Page 19: ...ures above 3 Enter configuration mode by reading the ENTER SETUP label CIPHER 1022R will should activate a L H L H L H beep 4 Read the DEFAULT label to choose the default settings CIPHER 1022R should...

Page 20: ...1 For most of the settings only 1 label is needed to complete the setting and CIPHER 1022 will activate a L H beep as an echo 2 Modification of the following settings require reading of 2 labels Code...

Page 21: ...rt beep b Read HEXADECIMAL LABELS Each prefix postfix character is composed of 2 hexadecimal labels Please reference ASCII Table Kbd Wedge Map Table for correct assignment CIPHER 1022 will echo a shor...

Page 22: ...E U 6 Down F8 6 F V f v F V 7 Left F9 7 G W g w G W 8 BS F10 8 H X h x H X 9 HT F11 9 I Y i y I Y A LF F12 J Z j z J Z B Right ESC K k K C PgUp Exec L l L D CR CR M m M E PgDn N n N F F1 O _ o Dly O _...

Page 23: ...UPCA Emulate Type PC AT CODE ID N Language US Prefix Function Key Emulation N Postfix Capital Lock AUTO Trailer CR Inter_Character Delay 0 ms Beeper LOW SHORT Code Read Check Char Misc V87001 152 ver...

Reviews: