Plumbing Instructions
This equipment is to be installed to comply with the applicable federal, state or local plumbing codes.
Connect the 3/8” compression fitting of the provided stainless steel braided hose to the connection from the
filtered, cold water line.
Fittings on the hoses are 3/8” compression type fittings; thread sealant or Teflon tape is not necessary.
Make connections snug, but do not over tighten.
Turn water ON and check for leaks.
The ¾” inside diameter clear vinyl ribbed hose connects the outlet fitting of the drain box to the drain
(located on the right hand, bottom, rear corner). Run this hose to the floor drain or floor sink.
NOTE: The Sabre requires a minimum of 35 PSI of line pressure to have the auto fill system for the steam
tank function properly.
Electrical Instructions
After you make sure your receptacle and circuit are properly rated (see specifications chart on page 16) for
your model, then install a matching plug on the power cord provided with the Sabre.
North American Configuration
Outside of North America
Green
Ground
Green & yellow
Ground
White
110 V
Brown
220 V
Black 110
V
Blue
Neutral
Make sure that the On/Off electronics switch (red rocker)
and the heating element breaker on the Sabre are in the
OFF (0) position, then plug the power cord into the
receptacle.
IMPORTANT -
If the voltage on the receptacle used is less
than 210 Volts, Synesso recommends installing an In-Line
Buck-Boost transformer to increase this voltage.
•
1 and 2 Group 220 Volt Machines require a 1.0
KVA transformer
•
3 Group 220 Volt Machines require a 1.5 KVA
transformer.
Start-Up Instructions
1. To fill the coffee brew tanks, turn the water ON.
2. Switch the electronics On/Off switch to ON. This activates the machine’s water auto-fill feature for
the steam tank and the electronics, but NOT the heating elements.
Power Cord wire
connections for plug
installation
: