![Synesso Sabre Owner'S Manual Download Page 3](http://html.mh-extra.com/html/synesso/sabre/sabre_owners-manual_1420892003.webp)
2
Label Locations
See this label on the electrical box
See this label on the end of the electrical cord.
See this label on the on inside edge of the frame under the drain tray on the front left side.
NOTE
: For single line 220 vac use:
•
White wire as supply
•
Black wire as neutral
•
Green wire as earth (ground)
Materials Information
•
All stainless steel that comes into contact with the water supply, used to fabricate Synesso
espresso machines is 300 series
•
All brass fittings are low lead per the CA360 specifications or better
•
All electronic devices are lead free
•
All gaskets are made from a food contact safe material
Test Information
•
Brew (coffee) tanks are hydrostatically tested to 375 psi
•
Steam tanks are hydrostatically tested to 75 psi
•
The electrical system is subject to an electrical withstand test of: 1.20 kvac, at 5.00 mA, for 1
(one) second
This equipment is to be installed to
comply with the applicable federal,
state or local plumbing codes.