11
•
If a delay time of more than 2s is desired, this can be programmed by pressing a line key in accordance
with the following code:
Volume 1 = 5s, Volume 2 = 10s, Volume 3 = 15s, Volume 4 = 20s
•
When a key is pressed the LED of the key begins to flash. The input can be corrected at any time by
pressing another key. When the desired delay time has been selected, it is programmed by removing
the program plug.
Note:
Whenever the program plug is inserted the time which was programmed previously is cleared for
safety reasons and a value of 2s is preset.
6.2 Programming the Pump Operation
The Sabre Duo/Quattro Electronics control unit can also activate the pump when opening the main valve of
the boiler to prevent the boiler from emptying if the pressure in the water circuit should become too low.
The pump is programmed as follows:
•
Program plug JP2 not inserted = pump is activated when the main valve of the boiler is opened
7. Setting Portions
-
The "Setting" Section is Divided into 5 Subsections
7.1 Setting all Groups Together
The Sabre Duo/Quattro Electronics can set the individual volumes of several or all the groups in one
operation. This is done as follows:
1. Switch the "Set / Operation" switch to the "Set" position. The machine is then in the setting mode.
2. Press the "Stop/ continuous 5" keys of all the groups to be set. All of the LEDs of volumes 1 to 4 light up
to acknowledge this input.
3. Select a volume of a chosen group. The LED of this key and the corresponding LED of the selected
groups begin to flash. Water is dispensed.
4. When the desired volume of water is delivered, press the same key again. The LED of this key and the
corresponding LEDs of the selected groups continue to flash and the flow of water is stopped. While the
LED is flashing (15s). The volume button can be pressed again starting the flow of water to obtain the
desired volume.
5. Switch the "Set / Operation" switch to the "Operation" position.
7.2 Setting Separately
The Sabre Duo/Quattro Electronics also allows you to set all groups individually. This is done as follows:
1. Switch the "Set / Operation" switch to the "Set" position.
2. Then press the "Stop/ Continuous 5" key of the group to be set. All of the LEDs of volumes 1 to 4
light up to acknowledge this input.
3. Select a line. The LED of this key begins to flash. See 7.1
7.3 Setting the 5th Button “Stop/Continuous 5”
The Sabre Duo/Quattro Electronics can dispense a set portion by means of the "Stop/ Continuous 5" key.
The procedure for programming the 5th portion is slightly different to that for the other volumes. The "Stop/
Continuous 5" key is a multi-function key with the following functions:
•
STOP (interrupt a dispensing process) - possible whenever the group is active
•
Dispense a portion which has not been set (the procedure is activated by pressing the "Stop/
Continuous 5" key and is terminated by pressing the key again) or
•
Dispense a set portion (the procedure is activated by pressing the " Stop/ Continuous 5" key and is
terminated automatically when the set amount has been reached)
The setting procedure is:
1. Switch the "Set / Operation" to the "Operation" position
2. Press the "Stop/ Continuous 5" key of a group. The green LED of the group lights up and water flows.
3. Switch the "Set / Operation" to the "Set" position. The green LED of the group turns off, the flow of water
stops and the machine is now in the setting mode for line 5