Synesso Sabre Owner'S Manual Download Page 12

 

11

  If a delay time of more than 2s is desired, this can be programmed by pressing a line key in accordance 

with the following code: 

Volume 1 = 5s, Volume 2 = 10s, Volume 3 = 15s, Volume 4 = 20s 

  When a key is pressed the LED of the key begins to flash. The input can be corrected at any time by 

pressing another key. When the desired delay time has been selected, it is programmed by removing 
the program plug. 

Note: 

Whenever the program plug is inserted the time which was programmed previously is cleared for 

safety reasons and a value of 2s is preset. 
 

6.2 Programming the Pump Operation 

The Sabre Duo/Quattro Electronics control unit can also activate the pump when opening the main valve of 
the boiler to prevent the boiler from emptying if the pressure in the water circuit should become too low. 
The pump is programmed as follows: 

  Program plug JP2 not inserted = pump is activated when the main valve of the boiler is opened 

 

7. Setting Portions 

-

 

The "Setting" Section is Divided into 5 Subsections 

7.1 Setting all Groups Together 

The Sabre Duo/Quattro Electronics can set the individual volumes of several or all the groups in one 
operation. This is done as follows: 
1.  Switch the "Set / Operation" switch to the "Set" position. The machine is then in the setting mode. 
2.  Press the "Stop/ continuous 5" keys of all the groups to be set. All of the LEDs of volumes 1 to 4 light up 

to acknowledge this input. 

3.  Select a volume of a chosen group. The LED of this key and the corresponding LED of the selected 

groups begin to flash. Water is dispensed. 

4.  When the desired volume of water is delivered, press the same key again. The LED of this key and the 

corresponding LEDs of the selected groups continue to flash and the flow of water is stopped. While the 
LED is flashing (15s). The volume button can be pressed again starting the flow of water to obtain the 
desired volume. 

5.  Switch the "Set / Operation" switch to the "Operation" position. 

 

7.2 Setting Separately 

The Sabre Duo/Quattro Electronics also allows you to set all groups individually. This is done as follows: 

1.  Switch the "Set / Operation" switch to the "Set" position. 
2.  Then press the "Stop/ Continuous 5" key of the group to be set. All of the LEDs of volumes 1 to 4 

light up to acknowledge this input. 

3.  Select a line. The LED of this key begins to flash. See 7.1 

 

7.3 Setting the 5th Button “Stop/Continuous 5” 

The Sabre Duo/Quattro Electronics can dispense a set portion by means of the "Stop/ Continuous 5" key. 
The procedure for programming the 5th portion is slightly different to that for the other volumes. The "Stop/ 
Continuous 5" key is a multi-function key with the following functions: 

  STOP (interrupt a dispensing process) - possible whenever the group is active 

  Dispense a portion which has not been set (the procedure is activated by pressing the "Stop/ 

Continuous 5" key and is terminated by pressing the key again) or 

  Dispense a set portion (the procedure is activated by pressing the " Stop/ Continuous  5" key and is 

terminated automatically when the set amount has been reached) 

 
The setting procedure is: 
1.  Switch the "Set / Operation" to the "Operation" position 
2.  Press the "Stop/ Continuous 5" key of a group. The green LED of the group lights up and water flows. 
3.  Switch the "Set / Operation" to the "Set" position. The green LED of the group turns off, the flow of water 

stops and the machine is now in the setting mode for line 5 

Summary of Contents for Sabre

Page 1: ...Artistry Ingenuity Understanding Owner s Manual Sabre Espresso Machines ...

Page 2: ...Always have the steam wand tip covered or inserted in the product to be steamed before opening the steam valve Never remove the steam wand from the product that is being heated when the valve is open Never remove the portafilter from the machine during the brewing process Keep water and moisture away from any electrical device or live power Steam tank water is heated to 260 F 126 C Use caution aro...

Page 3: ...th the water supply used to fabricate Synesso espresso machines is 300 series All brass fittings are low lead per the CA360 specifications or better All electronic devices are lead free All gaskets are made from a food contact safe material Test Information Brew coffee tanks are hydrostatically tested to 375 psi Steam tanks are hydrostatically tested to 75 psi The electrical system is subject to a...

Page 4: ...ess Steel Braided Hose 84 Stainless Steel Braided Hose Qty 2 Tamper 58 mm Fitting 3 8 Pipe x 3 8 Compression Accessory Package Synesso 3oz Shot Glass A combination of portafilters based on the size of the machine not all items below are included Model 3 Group 2 Group Portafilters 4 3 Double Spout 3 2 Single Spout 1 1 Double Basket 3 2 Single Basket 1 1 Blind Basket 1 1 Please have your Serial Numb...

Page 5: ...stem designed to match the needs of your specific area Most water filtration systems require periodic maintenance cartridge or filter replacement This is vital to the proper functioning of the machine and the quality of the espresso served Follow the instructions provided by your water treatment system for proper installation Note Improper water filtration can result in water damage inside the mac...

Page 6: ...s TDS 30 to 200 ppm parts per million Total Hardness in ppm Less than 85 ppm Total Hardness in grains 3 to 5 grains divide ppm by 17 1 to get grains pH 6 pH to 8 pH Chloride 0 ppm any Chlorides can be corrosive and harmful Total Alkalinity Less than 100 ppm Chlorine 0 ppm Iron 0 ppm Water to steam tank Electrical requirements 1 Group 110v 110v 60 hz 20 amp 1 Group 220v 220v 50 60 hz 16 amp 2 Group...

Page 7: ...nd circuit are properly rated see specifications chart on page 16 for your model then install a matching plug on the power cord provided with the Sabre North American Configuration Outside of North America Green Ground Green yellow Ground White 110 V Brown 220 V Black 110 V Blue Neutral Make sure that the On Off electronics switch red rocker and the heating element breaker on the Sabre are in the ...

Page 8: ...e brew gauge 8 Set the pump pressure to 9 Bar To do this locate the pump adjusting screw on the right side of the brass pump housing Loosen the lock nut and turn screw with a screwdriver Clockwise to INCREASE pressure Counterclockwise to DECREASE pressure 9 Please allow at least hour of warm up time before using your Sabre espresso machine to brew shots or steam milk The steam gauge should read a ...

Page 9: ...minal 9 Hot water key Terminal Input of the tea key The return line is connected to terminal 8 10 Level Probe High Input from the Level probe to control the water level into the boiler 11 Earth Terminal Ground to Frame 12 Level Probe Low 13 Not Used 14 Common lead for contact assemblies L1 15 Pump Control Terminal To the pump relay 16 Group 2 Control Terminal Relay contact to the solenoid of group...

Page 10: ...urn line is connected to terminal 8 11 Set Operation switch Terminal The return lead is connected to terminal 8 12 Earth Terminal Important Please read the section EARTHING in this manual 13 Steam Level Probe High 14 Not Used 15 Not Used 16 Not Used 17 Common lead for contact assemblies L1 18 Pump Control Terminal To the pump relay 19 Group 1 Control Terminal Relay contact to the solenoid of group...

Page 11: ...issioning The Sabre Duo Quattro Electronics control unit must be connected according to our installation specifications After the coffee machine has been fully wired connect the keypads to the control unit using the ribbon cable enclosed In the operating instructions the term volume is used for the portion keys The double function of the STOP key is designated Stop Continuous 5 Volume 1 Volume 2 V...

Page 12: ...ered press the same key again The LED of this key and the corresponding LEDs of the selected groups continue to flash and the flow of water is stopped While the LED is flashing 15s The volume button can be pressed again starting the flow of water to obtain the desired volume 5 Switch the Set Operation switch to the Operation position 7 2 Setting Separately The Sabre Duo Quattro Electronics also al...

Page 13: ... The Sabre Duo Quattro Electronics can also proportion hot water for tea using a timer This timer is set as follows 1 Switch the Set Operation to the Set position 2 Press the tea key Hot water flows out 3 When the cup is full press the tea key again The quantity of the hot water is set The system does not have a correction facility for setting the hot water timer If the setting must be corrected t...

Page 14: ... Duo Quattro Electronics is interrupted DigiZone Controls A custom PID Electronics System The 5 Zone Control System for 2 3 Group Models Temperature readout for selected Zone 1st Group Brew Tank 2nd or Center Group 3rd Group 3 group models only Steam Tank 4 Controls 1st Element Steam Tank 5 Controls 2nd Element The 2 Zone Control System for 1 Group Models 1 LED is the brew tank 4 LED is the steam ...

Page 15: ...at sea level Temperature as it Relates to Pressure in the Steam Tank Temperature Bar PSI 230 40 to 50 6 to 8 240 75 to 85 10 to 12 250 1 10 to 1 20 15 to 17 260 1 40 to 1 60 23 to 25 270 1 80 to 2 00 30 to 32 Removal of Right Hand Side Panel CAUTION This should ONLY be done by Qualified Personnel Use a 5 8 wrench remove the 4 nuts O rings the steam lever will stay attached to the panel 1 Adjust th...

Page 16: ... of the coffee is level for even brewing 5 Engage the portafilter into the brew group that has the correct temperature setting for this espresso roast and pull firmly to the right to set the seal 6 Press the desired volume button on the keypad 7 If the coffee is ground dosed and tamped to the proper consistency it should take about 20 to 25 seconds to brew a 2 oz double shot Milk Steaming 1 The st...

Page 17: ... important to thoroughly rinse the blind filter basket and repeat back flushing several times with clean water to clear the system of any detergent residue Cleaning 1 Clean the surface of the machine using a soft damp cloth Avoid using abrasive cleaners or cleansing pads Take extra care on the mirror finish stainless steel surfaces 2 Make sure the steam wands and tips are free of milk built up It ...

Page 18: ...the motor Important Machine service and repair procedures must be performed by authorized service personnel Sabre Machine Specifications Model 2 Group 3 Group Voltage 220 220 Hertz 50 60 50 60 Amps max draw 28 36 Brew and Steam Specifications Watts per Element Steam Tank 2000 x 2 2500 x 2 Total Steam Element Wattage 4000 5000 Steam Tank Capacity Liters 7 7 12 3 Watts per Element Brew Tank 700 x 2 ...

Page 19: ...Less than 85 ppm Total Hardness in grains 3 to 5 grains divide ppm by 17 1 to get grains pH 6 pH to 8 pH Chloride 0 ppm any Chlorides can be corrosive and harmful Total Alkalinity Less than 100 ppm Chlorine 0 ppm Iron 0 ppm Any part which is determined to be defective in materials or workmanship should be returned to Synesso or to an authorized service location shipping costs prepaid as Synesso de...

Page 20: ...then a total system reboot is required Section B Total System Reboot 1 Turn red on off power switch OFF and then turn the element breaker OFF 2 This can be difficult and may require assistance press and hold zone up arrow down arrow and set buttons simultaneously and turn the power switch ON Continue to hold all buttons during the start up process and wait until the electronics turn on momentary t...