DigiZone
™
Control Reset & Reboot Guide
If your electronics are out of the parameters you set and you are unable to make any adjustments, follow
these steps to reset the electronics.
Section A – Reset DigiZone™ Electronics
1. Turn the red on/off
power switch
OFF, then back ON
2. Scroll the
zones
and press
set
to check the set points, reset if required
3. Press and hold the
up arrow,
then press and hold the
zone
button, hold both buttons together for 5
seconds to enter the common parameter adjusting mode.
•
1
st
parameter is the
high alarm
, set to 275° F – holding the
set
button and using the
up
and
down arrow
keys. Press
zone
to go to the next parameter
•
2
nd
parameter is the
low alarm
, set to 125° F
•
3
rd
parameter is the
auto fill probe
delay
, factory setting is 5 seconds
•
4
th
- 8
th
parameters are the
temperature offset for Zone 1, 2, 3, 4 & 5 respectively.
The
factory offsets for this machine are located on page 2 under the serial number
4. Press
zone
button to return to the operational mode
If the electronics do not respond to the above procedure, then a total system reboot is required
Section B – Total System Reboot
1. Turn red on/off
power switch
OFF and then turn the
element breaker
OFF
2. This can be difficult and may require assistance, press and hold
zone
,
up arrow
,
down arrow
and
set
buttons simultaneously, and turn the
power switch
ON. Continue to hold all buttons during the
start up process and wait until the electronics
turn on
momentary,
then off
and
then on
again
BEFORE you release the buttons. If 2
ON
cycles are not achieved, please try again.
3. Release all 4 buttons
4. This is a total system reboot and all of your parameters and your temperature set points will need to
be reentered. The electronics will show the factory temperature set points. Follow steps 1 -4 in
section A to program your set points.
5. Turn the
element breaker
ON
Section C – Fill in your Temperature Set Points for Reference
Temperature
1 Group
Factory
2 Group
3 Group
Factory
Zone
1
200°
200°
Zone
2
250°
200°
Zone 3
N/A
N/A
* OFF
200°
Zone 4
N/A
N/A
250°
Zone 5
N/A
N/A
250°
•
On a 2 group machine, lower the temperature setting for zone 3 until it reads OFF
Section D - Scroll Mode
•
Turn ON by pressing
up & down arrows
together until scrolling starts
•
Turn OFF scroll mode by pressing either the
set
or
zone
button