14
3.3.2
Reinstating the Internal Gas Valve Regulator for Natural Gas:
A)
Remove the Brass Regulator Cover Screw and put to one side.
B)
Take out the Blocking Pin and Spring from the centre of the Plastic
Regulator Adjustment Screw and keep safe for when you need to convert
back.
C)
Connect your manometer to the Outlet Pressure Post (Follow steps 2.2 C
& D) and set burner to 15mbar.
D)
Replace the Brass Regulator Cover Screw.
Nat Gas Data Plate:
Remove the Nat Gas Data Plate from the documents supplied with this appliance
and cover over the LPG Data Plate which can be found on this unit.
This unit is now ready to be used for G20, G25 & G25.3A Gas types.