17
17
NOTe 1:
Speed of wire shift can also be adjusted and changed during wel
-
ding. Either a potentiometer or a remote control UP/DOWN can be used.
NOTe 2:
bottom display shows speed of wire shift only if red lED SETTING
and lED “m/min” are on.
Adjustment of other welding parameters
Controlling electronics of machines PROCESSOR and SyNERGIC enables ad
-
justment of the following welding parameters:
• Time duration of pre-gas (time of protective gas blow before the begi
-
nning of welding process).
• Time of start of wire shift speed - function SOFT START (time of start from
minimum shift speed up to value of adjusted welding wire speed, only
PROCESSOR).
• Approaching wire speed (only SyNERGIC).
• Speed of wire shift m/min (speed of wire shift during welding).
• Time of switching off interval of welding voltage on arc opposite wire
shift: „burning out“ of wire towards the torch top.
• Time of post-gas after finishing welding process.
Setting PRE-GAS
Press button SET until you switch on lED marked in the picture.
Use the potentiometer to set up required value of pre-gas time within se
-
conds.
Adjustment of wire burning out
Press button SET until you switch on lED marked in the picture.
Use the potentiometer to set up required value of wire burning out within
seconds.
Setting of POST-GAS
Press button SET until you switch on lED marked in the picture.
Use the potentiometer to set up required value of post-gas time 0-5 seconds.
Adjustment of the start of wire speed
- the function SOfT-START
Function SOFT-START secures an error-free start of the welding process.
SOFT-START enables adjustment of the following parameters:
• the start time of welding wire speed from minimum speed up to adjusted
welding speed
• approaching wire speed before welding arc ignition
both the functions work in a different way. For a softer start approaching
wire speed is recommended - the second option.
Adjustment - the start time of welding wire speed
Press the button SET until the lED is on, marked in the picture.
PROCESSOR
SyNERGIC
Adjust the required value of the start time of the wire speed shift with a
potentiometer within the range of 0-5 seconds.
Adjustment of the approaching wire speed shift
ATTeNTiON!
before adjusting the approaching speed of the wire, switch off
the start time of the wire speed shift - set the value „0“.
Adjustment of the approaching speed - „the wire outlet“ is possible only
when the function of the start time of wire speed is switched off - it means
you have to set the value „0“ according to the description in the previous
chapter.
Table 4 - Range of value settings -
Machines processor and SyNeRgic
pre-gas
time
approach
speed
SOFT START
wire feed
speed
spot time
lag time
burn out
post-gas
time
(s)
(m/min)
(s)
(m/min)
(s)
(s)
(s)
(s)
processor
0 - 3
-
0.1 - 5
1 - 20
0.5 - 5
0.2 - 2
0 - 0.99
0.1 - 10
SyNeRgic
(only 400, 500 W)
0 - 3
0.5 - 20
-
1 - 20
0.5 - 5
0.2 - 2
0 - 0.99
0.1 - 10