22
110 Series Ice and Water Dispensers
Ice transport tube replacement
Models 110FB400A/W, 110CR400A/W
1. Remove top and rear access panel from dispenser (lower front panel in
freestanding unit).
2. Disconnect existing ice tube from engaging pin on transport tube bracket in ice
storage bin evaporator and pull down through dispenser chase.
3. Disconnect opposite end of tube from ice machine.
4. Run end of new ice transport tube with 3/16" (5mm) hole through ice transport
tube knock-out, (Fig. 5G) in back of dispenser or through counter into bottom of
dispenser, being careful to avoid any bends with less than 6" (153mm) radius.
5. Insert tube in internal chase in rear inside corner of dispenser (left side as you
face dispenser) and push up into storage area.
6. Push the 3/16" (5mm) hole near end of tube into pin on ice tube bracket
(see drawing below).
Steps 7-8 for units with RIDE ice machines only
7. Install supplied insulation to run of transport tube required for your site, leaving
approximately 2" (51mm) of tube exposed at free end.
8. Check that insulated tube runs continuously uphill to dispenser with no dips.
Correct installation of ice transport tube is critical to RIDE ice machine performance. Replacement ice
transport tubes for RIDE ice machines must be insulated and run continuously from ice machine to
dispenser with no dips or bends with a radius of less than 6" (153mm).
!
A
A
1"
(25mm)
Section A – A
3/16" (5mm)
dia. hole
Ice transport tube replacement
Model 110CT400A/W
Only use tubing supplied by Follett Corporation.
!
1
2
3
4
TIGHTEN
CLAMP