System Time
System Time is defined as the user's time of day derived from the Line Frequency Under Test plus a user
entered offset and is calculated as follows:
LOCAL TIME + USER ENTERED TIME DEVIATION TIME DEVIATION
User Interface
Using
See “F27 – FTM III Configuration”, page 63
, available from:
•
Front panel display
•
Command Line (Serial Port & Network Port)
Also available using the web interface.
FTM Display
Data Available once-per-second:
•
System Frequency
•
Frequency Deviation
•
Time Deviation
•
System Time
•
Local Time
•
CPU-Aware: No
Installation
No installation is required when the FTM is factory installed in the XLi. The following installation
instructions apply only to an FTM card installed by the customer later on.
Supplied with the purchase of a separate FTM card:
Range:
Local Time ±99.999 s
Accuracy:
1 ms + the absolute value of { (REF FREQ / FUT) -1} *1.5
E.g., at 60.05 Hz and 59.95 Hz, the accuracy is 1 ms +
Absolute value of {-0.833 ms} * 1.5 = 2.25 ms
RS-422 PORT:
Selectable Ranges (from Front Panel Keypad)
baud rate
600 - 38400
data bits
7 - 8
parity
even, odd, none
stop bits
1, 2