![Symmetricom XLi User Manual Download Page 174](http://html.mh-extra.com/html/symmetricom/xli/xli_user-manual_1419618174.webp)
XLi Time & Frequency System
163
XLi-man, Issue 8, 6/17/2008, Rev. H
2
5
1
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
To change the INPUT MODE and HQ TIME REFERENCE, send a command using the following format:
F123<SP>B<N><SP>C<SP><CONFIG><SP><REF><LT>
where:
For example, enter:
F123 B3 C SEC HAVE QUICK 1PPS
The XLi changes INPUT MODE to HAVE QUICK 1PPS, changes HQ TIME REFERENCE to
SECONDARY, and responds:
OK
F
= ASCII character F.
123
= function number.
<SP>
= ASCII space character.
B
= ASCII character B to denote Option Bay number follows
<N>
= Option Bay Number, 1 through 10.
C
= ASCII character to denote “Configuration of Time Reference”
<CONFIG> = Option Board Configuration: PRI, SEC, or STBY
<REF>
= Option Board Reference: 1PPS, HAVE QUICK, or HAVE QUICK 1PPS
<LT>
= line terminator; for output strings (a carriage return and line feed) for input strings
(a carriage return only).