Command Line
Viewing Card Status
For status of the Have Quick 1PPS option board, send a command using the following format:
F123<SP>B<N><SEP>S<CR>
For example, enter:
F123 B3 S
The XLi responds (example only):
F123 B3:
HQ PART NUMBER 87-8016-3
SOFTWARE 192-8008v1.6
FPGA 184-8016v02
HQ REF STATUS LOCKED (or UNLOCKED)
HQ PLL LOCKED (or UNLOCKED)
Configuring INPUT MODE and HQ TIME REFERENCE
To display the INPUT MODE and HQ TIME REFERENCE configuration of the card, send a command
using the following format:
F123<SP>B<N><SEP>C<CR>
where:
For example, enter:
F123 B3 C
The XLi responds, for example:
F123 B3 PRIMARY 1PPS
F
= ASCII character F
123
= function number
<SP> = ASCII space character one or more
B
= ASCII character to denote Option Bay number follows
<N>
= Option Bay Number, 1 through 10
S
= ASCII character for “Status Request”
C
= ASCII character for “Configuration of Time Reference”
<LT> = line terminator; for output strings (a carriage return and line feed) for input
strings (a carriage return only).