TimeSource 3500
255
Troubleshooting
097-72050-01 Issue 7: August 2003
2
3
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Table K. Front Panel Items
Name
State
Description
Action
Status GPS
Off
System is not powered.
If in warm-up, none required.If
there is no power, apply power.
Green
GPS is successfully tracking
satellites, or is in warm-up.
None required.
Yellow
A GPS event has occurred.
None required.
Red
A GPS event, which has existed
per the user alarm setting, has
escalated to a minor alarm.
Refer to Table L to determine
which type and combination of
antenna alarms exist, and the
recommended action.
Status SYS
Off
System is in warm-up mode or is
not powered.
If in warm-up, none required. If
there is no power, apply power.
Green
The output signal is PRS.
None required.
Red
The system has been in holdover
per the user alarm setting, or
there is a hardware fault.
Refer to Table L to determine
which type and combination of
alarms exist, and the
recommended action.
Alarms CRIT
Off
There is no critical alarm.
None required.
Red
A critical alarm has occurred
because of a hardware failure.
Replace the plug-in card, using
Procedure J.
Alarms MAJ
Off
There is no major alarm.
None required.
Red
The system has been in holdover
per the user alarm setting.
Refer to Table L to determine
which type and combination of
antenna alarms exist, and the
recommended action.
Summary of Contents for TimeSource 500
Page 1: ...TimeSource 3500 GPS Primary Reference Source 097 72050 01 Issue 7 August 2003 ...
Page 6: ...6 TimeSource 3500 Contents 097 72050 01 Issue 7 August 2003 ...
Page 161: ...4 Chapter TL1 Reference This chapter provides information for using the TL1 language ...
Page 271: ...6 Chapter Specifications This chapter provides equipment specifications ...
Page 297: ...Index ...