If using time-of-day (TOD), and the device receiving the time code
accepts an RS-232 signal instead of an RS-422 signal (for
example, a Cisco router), an RJ-422–to–RJ-232 TOD Converter Kit
is required (ordered separately, part number 093-72000-98).
The RJ-422–to–RJ-232 TOD Converter Kit consists of a mounting
plate with a female RJ-45 connector, a female DB-25 connector, a
TOD converter, and two screws.
Install the converter anywhere (for example, on unused space on a
rack) within 1,000 cable feet of the TimeSource 3500 shelf, and
within 50 cable feet of the device receiving the time code.
The user must supply two cables. One cable is a Category 5 four-
pair RS-422 cable, 1,000 feet maximum, with RJ-45 connectors on
each end. Route this cable between the TimeSource 3500 Shelf
and the converter.
The other cable is an RS-232 data communications cable, 50 feet
maximum, with a 25-pin male D-type connector and another
connector determined by the device receiving the time code. Route
this cable between the converter and the device receiving the time
code.
Summary of Contents for TimeSource 500
Page 1: ...TimeSource 3500 GPS Primary Reference Source 097 72050 01 Issue 7 August 2003 ...
Page 6: ...6 TimeSource 3500 Contents 097 72050 01 Issue 7 August 2003 ...
Page 161: ...4 Chapter TL1 Reference This chapter provides information for using the TL1 language ...
Page 271: ...6 Chapter Specifications This chapter provides equipment specifications ...
Page 297: ...Index ...