74
TimeProvider 5000 User’s Guide
098-00028-000 Revision F – May, 2012
Chapter 2 Installing
Signal Connections
Figure 2-19. Output Connections for T1 and Expansion Versions of I/O Module
E1 Connections
Two of the four coaxial ports on the 090-50311-01 and 090-50312-01, and
090-50315-01 versions of the I/O module (see
) are
software configurable as either E1 input or output ports. These ports are mini-BNC
male ports, except for the 090-50315-01, which uses SMB male connectors. They
can provide or receive the following signal types:
2.048 Mb/s (G.703/9)
2.048 MHz (G.703/13)
The 090-50311-01 version of the I/O module (
) also has two mini-BNC
male ports that are dedicated E1 output ports with the following signal types:
2.048 Mb/s (G.703/9)
2.048 MHz (G.703/13)
T1 Connections
The 090-50314-01 version of the I/O module has two RJ-45 ports that are software
configurable as either T1 input or output ports (see
). They can provide
or receive the following signal types:
1.544 Mb/s (G.703)
1.544 MHz (G.703)
Note:
Amphenol mini-BNC connectors (031-70261) can be
used to create cables. Alternatively, Symmetricom sells a kit of
4 mini-BNC to BNC adapter cables (093-00068-000).
Note:
The T1 ports on t
he 090-50314-01 version of the I/O
module
can also be configured as E1 and 2048 kHz inputs or outputs
which meet the G.703 mask for impedance of 120 ohms, balanced.
Summary of Contents for TimeProvider 5000
Page 12: ...Table of Contents 12 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 16: ...List of Figures 16 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 20: ...List of Tables 20 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 56: ...56 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 Chapter 1 Overview Alarms ...
Page 534: ...Index W W 534 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...