3-7
MS-804FZY Specifications
Table 3-3. MS 804FZY Decode Distances
Symbol Density/
Symbol p/n /
Bar Code Type/
W-N Ratio
Bar Code
Content/
Contrast
1
Typical Working
Ranges
Guaranteed Working
Ranges
Near
Far
Near
Far
5 mil
64-17453-01
Code 39; 2.5:1
ABCDEFGH
90% MRD
1.6 in.
4.06 cm
4.9 in.
12.45 cm
2.5 in.
6.35 cm
4.0 in.
10.16 cm
7.5 mil
64-17452-01
Code 39; 2.5:1
ABCDEF
90% MRD
1.2 in.
3.05 cm
8.2 in.
20.83 cm
2.0 in.
5.08 cm
6.5 in.
16.51 cm
10 mil
Code 39; 1:2.5
ABCDE
90% MRD
0.7 in.
1.78 cm
11.4 in.
28.96 cm
1.25 in.
3.18 cm
8.7 in.
22.10 cm
13 mil
64-05303-01
100% UPC
12345678905
90% MRD
0.8 in.
2.03 cm
13.5 in.
34.29 cm
1.5 in.
3.81 cm
11.0 in.
27.94 cm
20 mil
60-01429-01
Code 39; 2.2:1
123
90% MRD
Note 2
18.5 in.
46.99 cm
Note 2
14.0 in.
35.56 cm
40 mil
64-17457-01
Code 39; 2.2:1
AB
90% MRD
Note 2
28.7 in.
72.90 cm
Note 2
21.0 in.
53.34 cm
55 mil
64-17458-01
Code 39; 2.2:1
CD
90% MRD
Note 2
33.4 in.
84.84 cm
Note 2
23.0 in.
58.42 cm
Notes:
1. CONTRAST measured as Mean Reflective Difference (MRD) at 650 nm.
2. Near ranges on lower densities (not specified) largely depend on the width of the bar code
and the scan angle.
3. Working range specifications at ambient temperature (23°C), pitch=15°, roll=0°, skew=0°,
photographic quality, ambient light<200 ft-c.
Summary of Contents for MiniScan MS-804FZY
Page 1: ...MiniScan MS 804FZY and MS 904HS Integration Guide...
Page 2: ......
Page 3: ...MiniScan MS 804FZY and MS 904HS Integration Guide 72 58197 01 Revision A September 2003...
Page 10: ...viii MS 804FZY and MS 904HS Integration Guide...
Page 16: ...xiv MS 804FZY and MS 904HS Integration Guide...
Page 58: ...5 4 MS 804FZY and MS 904HS Integration Guide...
Page 166: ...7 106 MS 804FZY and MS 904HS Integration Guide Numeric Bar Codes continued 4 5 6 7...
Page 168: ...7 108 MS 804FZY and MS 904HS Integration Guide...
Page 172: ...9 2 MS 804FZY and MS 904HS Integration Guide...
Page 182: ...Index 4 MS 804FZY and MS 904HS Integration Guide...
Page 183: ......