4-2
MS-804FZY and MS-904HS Integration Guide
MS-904HS Electrical Interface
Figure 4-1. MiniScan Connector
lists the pin functions of the MS-904HS interface.
Table 4-1. MS-904HS Electrical Interface
Pin
No.
Pin Name
Type*
Function
1
Trigger
I
Signals scanner to begin scanning session.
2
TXD
O
Serial data transmit output. Drives the serial data receive input on
the device communicating with the scanner.
3
RXD
I
Serial data receive input. Driven by the serial data transmit output
on the device communicating with the scanner.
4
Not used
5
Ground
Power supply ground input and signal ground reference.
6
Power
I
5.0 VDC ± 10%
7
CTS
I
Clear-to-send handshaking input line, used only in conjunction with
the RTS line. Optionally used by another device to signal the
scanner to begin transmitting data.
8
RTS
O
Request-to-send handshaking output line, used only in conjunction
with the CTS line. Optionally used by the scanner to signal another
device that data is available to send.
9
Beeper/
Download
I/O
During normal operation this signal functions as an external beeper
drive line. This signal can sink 50 mA of current to drive an external
beeper, and is normally pulled up. This signal is also used to begin
Flash Download operation when grounded externally during power
up.
*I = Input
O = Output
Summary of Contents for MiniScan MS-804FZY
Page 1: ...MiniScan MS 804FZY and MS 904HS Integration Guide...
Page 2: ......
Page 3: ...MiniScan MS 804FZY and MS 904HS Integration Guide 72 58197 01 Revision A September 2003...
Page 10: ...viii MS 804FZY and MS 904HS Integration Guide...
Page 16: ...xiv MS 804FZY and MS 904HS Integration Guide...
Page 58: ...5 4 MS 804FZY and MS 904HS Integration Guide...
Page 166: ...7 106 MS 804FZY and MS 904HS Integration Guide Numeric Bar Codes continued 4 5 6 7...
Page 168: ...7 108 MS 804FZY and MS 904HS Integration Guide...
Page 172: ...9 2 MS 804FZY and MS 904HS Integration Guide...
Page 182: ...Index 4 MS 804FZY and MS 904HS Integration Guide...
Page 183: ......