EN
34
"Start" can only be used on the digital inputs when the PLC input is disabled.
Connection example:
ATTENTION
The digital inputs DIN1…DIN6 are not galvanically isolated!
(Information on configuring the digital inputs are available in the operating manual "Operating Software
SycoDrive".)
6.8 Terminal 6
0…
63
CAN bus connection
–
Terminal 60…63
•
Voltage supply
o
An external 24 V DC voltage supply is required. This is connected between C_24V (61) and C_GND
(60).
o
The voltage range is 18...30 V.
•
High Speed CAN in accordance with ISO 11898 with a bit rate of 250 kbit/s.
•
A terminating resistance is not included. If required, this (120 Ohm) must be connected externally in
parallel between CAN_H (63) and CAN_L (62).
•
The maximum input voltage for CAN_H and CAN_L is +16V DC.
•
CANopen communication protocol with device profile CiA 402.
•
CAN-ID must be configured using the SycoDrive operating software.
See also Object description CANopen HF inverter e
@
syDrive 4624, 4625, 4626.
4-pin PCB connector (1,5 mm²), suitable for mating connector FMC 1,5/4-ST-3,5 (Phoenix)
Pin
Name
I/O
Meaning
60
C_GND
I/O
Ground
61
C_24V
I
24 V voltage to be supplied
62
CANL
I/O
Signal line CAN_L
63
CANH
I/O
Signal line CAN_H