Relay 1 and Relay 2
–
Terminal
30…35
: DFMC 1,5/3-ST-3,5 (Phoenix)
Technical Data
General
Connection method
Push-in spring connection
Nominal voltage (III/2)
160 V
Nominal current
8 A
Nominal cross section
1,5 mm²
Connection data
Conductor cross section solid min.
0,2 mm²
Conductor cross section solid max.
1,5 mm²
Conductor cross section flexible min.
0,2 mm²
Conductor cross section flexible max.
1,5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min. 0,25 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max. 1,5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.
0,25 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
0,75 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
16
Minimum AWG according to UL/CUL
16
Maximum AWG according to UL/CUL
24
Specifications for ferrules
Ferrules without insulating collar, according to DIN
46228
‑
1
Cross section: 0.25 mm²; Length: 5 mm...7 mm
Cross section: 0.34 mm²; Length: 7 mm
Cross section: 0.5 mm²;
Length: 8 mm...10 mm
Cross section: 0.75 mm²; Length: 8 mm...10 mm
Cross section: 1 mm²;
Length: 8 mm...10 mm
Cross section: 1.5 mm²;
Length: 10 mm
Ferrules with insulating collar, according to DIN 46228
‑
4 Cross section: 0.14 mm²; Length: 8 mm
Cross section: 0.25 mm²; Length: 8 mm...10 mm
Cross section: 0.34 mm²; Length: 8 mm...10 mm
Cross section: 0.5 mm²;
Length: 8 mm...10 mm
Cross section: 0.75 mm²; Length: 8 mm...10 mm
(For more information see the date sheet of the PCB connector.)
Temperature sensor, analog and digital inputs and outputs
–
Terminal
40…41
:
DFMC 1,5/10-ST-3,5 (Phoenix)
Technical Data
General
Connection method
Push-in spring connection
Nominal voltage (III/2)
160 V
Nominal current
8 A
Nominal cross section
1,5 mm²
Connection data
Conductor cross section solid min.
0,2 mm²
Conductor cross section solid max.
1,5 mm²
Conductor cross section flexible min.
0,2 mm²
Conductor cross section flexible max.
1,5 mm²
Conductor cross section flexible,
with ferrule without plastic sleeve min.
0,25 mm²
Conductor cross section flexible,
with ferrule without plastic sleeve max.
1,5 mm²
Conductor cross section flexible,
with ferrule with plastic sleeve min.
0,25 mm²
Conductor cross section flexible,
with ferrule with plastic sleeve max.
0,75 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
16
Minimum AWG according to UL/CUL
16
Maximum AWG according to UL/CUL
24
(For more information see the date sheet of the PCB terminal block.)