EN
19
PLC input signal
If the "Input for start:" is set to "Digital inputs", then starting is also possible via the PLC input.
•
"Start" can only be used on the PLC input if it is disabled in the digital inputs.
•
If the parameters are not transferred to the frequency inverter, then the settings will not take effect.
ATTENTION
Automatic start-up after a mains failure where a start signal is present at DIN1 or at the PLC input is
prevented. A positive edge is required at the start input.
CAN
The "Input for start" can also be set to "CAN". The "CAN node ID" can then be configured in the
"INPUTS/OUTPUTS" category under "CAN".
If the frequency inverter stops with an error, a start is only possible again if the button "Save on
inverter" of the software SycoDrive has been activated before (only for the combination "Input for start"
via Digital inputs and "Inputs for rated frequency" via SycoDrive),