EN
16
In addition, the frequency inverters have a CAN fieldbus interface, which can be used to network and
control the frequency inverter.
•
General:
o
CANopen communication protocol with device profile "CiA 402 electrical drives"
o
Electronic data sheet with communication objects in EDS file
•
Access to inverter parameters with CANopen service data objects (SDO)
(Further information can be found in Chapter 4.5.)
FW button
The FW button may only be used on explicit instructions by SycoTec and according to the appropriate
specifications.
Operation
The frequency inverter can be controlled in different ways:
•
With a remote control unit that is linked to the integrated digital inputs of the inverter.
•
Using a PLC that is linked to the integrated digital inputs of the inverter.
•
Using a PC that is directly connected via the mini USB connection.
•
CAN fieldbus controls with CANopen process data objects (PDO)
(Further information can be found in Chapter 4.5.)
Display
The operating status of the frequency inverter can be indicated with the help of two visible LEDs.
•
LED 1 red: Fault
•
LED 2 green: Operation
Green
–
LED 2
Red
–
LED 1
Meaning
OFF
OFF
Frequency inverter is switched off
ON
OFF
Inverter ready for operation
Flashing
OFF
Motor runs
ON / flashing
Flashing
Warning, warning code < 6 (flashes with the number of
the warning code)
ON / flashing
ON
Warning, warning code > 6
OFF
Flashing
Error, error code < 6 (flashes with the number of the
error code)
OFF
ON
Error, error code > 6
Flashes 2 times
OFF
Parameters transferred successfully from micro SD card
Flashes 2 times
Flashes 2 times
Fault when transferring parameters from micro SD card
Flashes 3 times
OFF
Parameters transferred successfully to micro SD card
Flashes 3 times
Flashes 3 times
Fault when transferring parameters to micro SD card
Standards
EN 61800
–
5
–
1 Adjustable speed electrical power drive systems
–
Part 5-1: Safety requirements - Electrical, thermal and energy
EN 61800
–
5
–
2 Adjustable speed electrical power drive systems
–
Part 5-2: Safety requirements - Functional
EN 61800-3 Adjustable speed electrical power drive systems
–
Part 3: EMC requirements and specific test methods
EN 60529 Degrees of protection provided by enclosures (IP Code)
Overload situation
Load class 2 according to DIN EN 60146-1-1
150% overload for 5s
Summary of Contents for e@syDrive 4624
Page 1: ...Operating Manual EN HF Inverter e syDrive 4624 4625 4626 ...
Page 2: ......
Page 22: ...EN 22 5 2 Mounting Frequency Inverter e syDrive 4625 and 4626 ...
Page 41: ...EN ...