Single Channel*
Single channel models use only a single frequency and, may use up to 50 profiles
Multi Channel*
Multi channel pagers use two or more frequencies (up to 50), To use profiles with a multi
channel unit, enter the same frequency twice with a different name (e.g. Ch1A, CH1b).
* Users may switch between profiles (or user profiles for the new user interface)
independent of the programming software. Please see operation manual for more
information.
Frequency
Enter the department frequencies here. For single channel models, enter the same
frequency for each profile. When you hit "Enter" after typing a name, the frequency will be
copied into the next profile.
Name (Profile)
Enter the name of the profile / channel here. There are a limited amount of characters to
choose from.
Note that characters are shown when user hovers over this tab with the
mouse.
S (Classic User Interface Only)
Frequencies that are checked in this column will be scanned from top to bottom.
Scan (New User Interface Only)
For each User profile you can select multiple Frequencies to scan. Simply enter the
number of the scan group (1 to 8) for each frequency you would like to be part of the scan
group. We recommend not to scan for “Alert” Networks, as scanning increase likelihood of
missing pages. If you decide to do so anyhow, please keep the number of scanned
channels as low as possible.
5.3 Step 3: Define Addresses
Settings for the address can be defined in the "Address" tab. This also includes the alert
type. Begin each new line with the entry of the call address (Tone 1, Tone 2).
Address name ("Mark")
The name entered here will be shown in the pager display when a call is received or
replayed. There are a limited amount of characters to choose from.
L (Long Tone)
No:
This address has 2 tones.