rechargeable battery which will take approximately 8 hours. Once the 
batteries are fully charged, the microscope illuminator will operate for 
approximately 40 hours without being connected to an electrical outlet.   
The M2251C can also be used while the power adapter is connected. If 
the power adapter is left connected to the microscope, the rechargeable 
batteries will stop charging when they are fully charged and there is no 
danger of over charging the batteries. The rechargeable batteries have a 
life of approximately 500 power cycles.     
    

 

PARTS AND ACCESSORIES 

 

MA10071 

4XD Objective 

MA10072 

10XD Objective 

MA10073 

40XRD Objective 

MA10512 

W10X Eyepiece 

MA10513 

W10X Eyepiece with pointer 

MA12004 

High-drive mechanical stage 

MA14281 

Power adapter for M2251C (4.5V, 1A) 

MA14283 

Cold Holder for M2251B or M2251CL (Pair) 

MA2201          120V, 20W bulb for M2251B 
MA2215 

3.4V, .06W LED for M2251C, M2251CL 

MA268 

Stage Clips 

MA336 

Dustcover 

         

 

CARE OF YOUR SWIFT SERIES M2250 MICROSCOPE 

 

Swift M2250 microscopes are designed to function satisfactorily with 
minimum maintenance. Certain components should be cleaned 
frequently to ensure ease of viewing. 
 

CLEANING – The front lens of the objectives (particularly the 40XRD) 

should be cleaned after use. First brush with a soft, camel hair brush or 
blow off with clean compressed air to remove dust particles. Then wipe 

gently with a soft lens tissue, moistened with optical cleaner (eyeglass or 
camera lens) or clean water and immediately dry with a clean lens 
paper. 

 

CAUTION - Objectives should never be disassembled by the user. If 

repairs or internal cleaning should be necessary, this should only be done 
by a qualified, authorized technician. 

Summary of Contents for M2250 Series

Page 1: ...Swift M2250 Series Microscope User and Care Manual SWIFT OPTICAL Enduring Quality and Technical Excellence...

Page 2: ...2...

Page 3: ...ocked on eyepieces objectives and stage clips and a slip clutch focusing system to protect gears from over focusing The M2250 Series is offered with several illumination options standard tungsten extr...

Page 4: ...s diaphragm M2251C M2251CL The function of the condenser is to provide full illumination to the specimen plane and to enhance the resolution and contrast of the object being viewed DISC DIAPHRAGM M225...

Page 5: ...ENS in attempting to transmit light through glass much of the light is lost through reflection Coating a lens increases the light transmission by reducing or eliminating reflection thus allowing more...

Page 6: ...ld be rotated to the next smaller aperture of the disc diaphragm or the iris diaphragm should be closed slightly This will increase contrast in the specimen s image 6 Move the slide to place the speci...

Page 7: ...14281 Power adapter for M2251C 4 5V 1A MA14283 Cold Holder for M2251B or M2251CL Pair MA2201 120V 20W bulb for M2251B MA2215 3 4V 06W LED for M2251C M2251CL MA268 Stage Clips MA336 Dustcover CARE OF Y...

Page 8: ...containing chemicals which may corrode your microscope Also be sure that the objectives are placed in the lowest possible position and the rotating head is turned inward and not protruding from the b...

Page 9: ...using the collar found on the coarse focusing controls between the knob and upright support A clockwise turn of this collar moves it toward the upright support and increases tension while a counter cl...

Page 10: ...not be centered properly on the stage and needs to be re positioned to be in the optical path E PROBLEM Image of the specimen goes out of the focus all by itself CORRECTION Use the tension control co...

Page 11: ...11...

Page 12: ...12 Swift Optical Instruments Inc 877 967 9438 www swiftoptical com...

Reviews: