Default parameter settings
0705
TTPM3 Printer/Encoder–Technical Manual
59
6.3 Parameter
Reference
96
Default
11
Min
1
96
Max
Baud rate
Stores the communication speed on the serial interface.
!H P 1 12
1200
bps
!H P 1 24
2400
bps
!H P 1 48
4800
bps
!H P 1 96
9600 bps
!H P 1 19
19200
bps
!H P 1 38
38400
bps
!H P 1 57
57600
bps
!H P 1 11
115200
bps
!H P 1 23
230400 bps, not recommended
!H P 1 46
460800 bps, not recommended
NOTE 1! –
If you set an invalid value, the baud rate will return to 115200 bps.
NOTE 2! –
The new baud rate will not be valid until after the parameters are stored
with the
!H S
command
2 Default
1 Min
2
2 Max
Flow-control
Select what handshaking to use on the serial interface.
!H P 2 1
Xon / Xoff
1
!H P 2 2
Hardware
2 Default
1 Min
3
2 Max
Printer type
Select what handshaking to use on the serial interface.
!H P 3 1
Standard (One consecutive [lower entry] + handfed-tickets [upper entry])
!H P 3 2
DCT
(Dual
Consecutive entries)
!H P 3 3
Card
dispenser
!H P 3 4
Fixed length, see parameter 34
!H P 3 5
Black mark mode, see parameter 36
NOTE! –
Must not be set to DCT when front loading is used!
1
DO NOT USE. If you send any type of binary data like graphics data, status requests etc. Xon / Xoff only work when plain text
is sent unidirectional
to
the printer. Graphics and status replies may well contain the Xon (11h) and Xoff (13h) characters and
will obstruct the communication.