Programming
30
TTPM3 Printer/Encoder–Technical Manual
0705
!Y
21 59
Hex
33 89
Decimal
Read ticket counter
This command reads out the value of the internal ticket counter from the control board.
This counter starts from 0 when the printer is new and is incremented by one fore each
completed !P sequence.
The result is sent as 12 decimal CR + LF
!Y 1
21 59 31
Hex
33 89 49
Decimal
Read retract counter
Reads out the internal retract counter. This counter is incremented by one for each ticket
that is retracted and thrown in the wastebasket.
To reset the counter to zero, send the command
!C1
The result is sent as 12 decimal CR + LF
NOTE! –
Retract function is only available on printers with
waste bin option (part of front load FL3 and FL4).
!Z
21 5A
Hex
33 90
Decimal
Set burn time
The burn time controls the print
density. It is used to set the heating so
that it is adequate for the thermal paper
used as ticket material. Set it to the
lowest burn time that gives acceptable
print quality.
Example:
!Z 20 <CR><LF>
sets burn time 640 µs
The burn time setting is stored in the
non-volatile memory.
Power off/on reset returns the setting
to default value.
CAUTION! –
A longer burn time put more load on the printhead, so do not
use a longer burn time than required for a clearly legible print.
Settings over 27 are not recommended.
ENQ
05
Hex
05
Decimal
Status request, immediate
The TTPM3 responds by sending the same 1 byte response to the host computer as is
sent as byte 1 in response to the !S command. The ENQ command is effected
immediately after receipt, whereas the !S command is effected in sequence when
received.
Setting Burn time
Print density
16
512
µ
s
Test
Lightest print
17
544
µ
s
Test
18
576
µ
s
Test
19
608
µ
s
Test
20
640
µ
s
Test
Default
21
672
µ
s
Test
22
704
µ
s
Test
23
736
µ
s
Test
24
768
µ
s
Test
25
800
µ
s
Test
26
832
µ
s
Test
27
864
µ
s
Test
28
896
µ
s
Test
29
928
µ
s
Test
30
960
µ
s
Test
31
992
µ
s
Test
Darkest print