Default parameter settings
56
TTPM3 Printer/Encoder–Technical Manual
0705
6 DEFAULT
PARAMETER SETTINGS
Some of the printer settings can be stored in non volatile memory so that they will be
used also after power OFF.
Each parameter has a parameter number (n) used when setting the parameter with the
command
!H P n v
.
Most parameter settings must be stored before being effective. Do this by setting them up
and then send
!H S
to store all settings in the non volatile memory.
NOTE 1! –
If you try to set a parameter to an invalid value, the parameter
will be set to the nearest valid value below, except for the baud
rate value which will return to the default value 115200 bps.
6.1 How the parameters are described
20
Default
16 Min
5
31
Max
Burn Time
Parameter number
Default value
Range
Description
SW 02001B
6.1.1 Default
value
The default values indicated are "factory default settings" you get by following the
procedure on the next page. These are not necessarily the settings that your printer was
originally delivered with because many printers have customized settings when delivered.
6.1.2 Examples
Command examples are formatted in
Courier
and typed in the same way as used in the
Swecoin TTP editor:
!H P 1 11<CR><LF>
Where
<CR>
means the carriage return character 12 decimal (hex 0C). Numbers
between less-than and greater-than characters, for example
<001><015>
, means 1 and
15 decimal (hex 1 and 13).