background image

Electrical Shock Hazard

 

Contacting live electrical wiring with power tools 

or hand tools can cause serious injury or death. 

Make sure all related circuit breakers are turned OFF. Test for 

live circuits or wiring inside any wall where installation of the 

Swanstone product requires cutting into a wall.

Electrocution Hazard

 

Water and other liquids conduct electric current 

and can create a short circuit, resulting in injury 

or death. Keep all liquids away from electrical cords and power 

tools. DO NOT create a short circuit between a source of 

electricity and a liquid by being in contact with both 

simultaneously.

General Information

Required Tools

m

    

100% clear silicone sealant

m

    

Circular saw with 60 to 80 tooth carbide blade

m

  

Saber saw (straight up and down travel) with bi-metal blade 

(14 teeth per inch)

m

 

Drill with 3/8” drill bit

m

 

Hole saw for shower faucet/shower head

m

 

Tape measure

m

 

Masking tape (2” wide works best)

m

 

Level

m

 

Compass or dividers (scribe the panel to the wall) 

m

 

Caulking gun

m

 

Clean paper towels or shop towels

m

  

2 x 4 lumber, as required for bracing (see Bracing 

Instructions)

m

  

Industrial grade, hot glue gun and glue sticks (optional)

m

 

Denatured alcohol

Kit Contents

Confirm that all parts of this kit have been included before 

beginning installation.

SS-6296, SSST-3696-1, SSST-6296-1, SSSQ-3696-1, and 

SSSQ-6296-1

 

One flat panel

DWP-369601 

One deco panel

SK-363672, SK-363696 

SK-364872, SK-364896 

SK-484896, SK-366072 

SK-366296 

Three flat panels     

Two corner moldings 

Two soap shelves 

One tube of  

color-coordinating 

silicone

STMK72-3636 

STMK96-3636 

STMK72-3662 

STMK96-3662 

SQMK72-3636 

SQMK96-3636 

SQMK72-3662 

SQMK96-3662

 

Three flat panels 

Two soap shelves 

One tube of  

color-coordinating  

silicone

For best results, use 100% clear silicone sealant for bonding this 

product to a properly constructed and prepared sub wall. You 

will need one tube of 100% clear silicone sealant (tube sized to 

fit a standard caulking gun) for every 1440 square inches or 10 

square feet, or, 4 to 10 tubes for an average shower. Follow the 

application recommendation located in the Panel Installation 

section of this manual.
It is NOT recommended to use GE brand of 100% silicone.

Unpackaging

m

  

Use care when opening the box so that you do not damage 

the panels.

m

  

This product is shipped to you or your retail center after 

careful inspection. After purchasing the kit, carefully unbox 

and inspect the product for any shipping damage that may 

have occurred. If damage is found, report it immediately to 

the store of purchase. After inspection and during installation, 

protect the products from construction damage by moving 

them to another room or area until ready to install.

m

  

Store panels in a flat area to avoid warpage until the time of 

installation. Do not store the panels outside of the original 

packaging in a vertical position.

m

  

Please use the model number located on the side of the 

box or the front of this manual when contacting us with 

questions concerning the installation of this unit.

m

 

 Make sure the walls are the correct size and are in good 

condition. Installation of damaged product will void the 

warranty.

Swan 

4 800-325-7008

Safety Guidelines 

General Information

SK-363672, SK-363696, SK-364872

SK-364896, SK-484896, SK-366072

SK-366296

STMK72-3636, STMK96-3636

STMK72-3662, STMK96-3662

SQMK72-3636, SQMK96-3636

SQMK72-3662, SQMK96-3662

Summary of Contents for Swan DWP-369601

Page 1: ... m Safety Guidelines m Kit Contents m Required Tools m Preparation Tips m Installation Procedure m Cleaning Maintenance m Surface Repair m Warranty Information R e a d a n d U n d e r s t a n d B e f o r e I n s t a l l i n g Form 193 05 16 www swanstone com ...

Page 2: ...anels Never install panels over damp walls or an existing mold condition CAUTION CAUTION Indicates a potentially hazardous situation which if not avoided may result in injury It may also be used to alert against unsafe practices Use Proper Installation Methods Follow all instructions related to wall surface preparation Failure to follow such instructions could cause the panels to detach from the w...

Page 3: ...mmend that shower compartments be equipped with support grab bars that comply with the most recent edition of ANSI A117 1 requirements Grab bars must be anchored to structural support wall studs behind the panels Do not rely on the panels only for grab bar support WARNING WARNING Indicates a potentially hazardous situation which if not avoided could result in serious injury or death Eye Protection...

Page 4: ...STMK72 3662 STMK96 3662 SQMK72 3636 SQMK96 3636 SQMK72 3662 SQMK96 3662 Three flat panels Two soap shelves One tube of color coordinating silicone For best results use 100 clear silicone sealant for bonding this product to a properly constructed and prepared sub wall You will need one tube of 100 clear silicone sealant tube sized to fit a standard caulking gun for every 1440 square inches or 10 sq...

Page 5: ...lm waxes or any other residues m If you are installing a recessed accessory cut the hole after the panel is installed and fully supported by the wall Remember to position the accessory between the wall studs Caulking Tips m Follow the instructions on the color match silicone sealant tube m When job is complete inspect all caulked areas for gaps and fill as needed m Clean up any excess silicone tha...

Page 6: ...damage incurred from the use of this material either in whole or in part by the buyer m This manual will give you basic instructions for the installation of the product in a step by step sequence that will work in most types of installations If you have an installation application that is not covered in this manual please call your local Swanstone distributor or contact Swan directly for additiona...

Page 7: ...wall measures less than the width of the panel cut the panel to fit the opening 1 Using a builder s square make sure the shower base is perpendicular to the side walls If the walls are out of square the bottom of all the panels may need to be cut to follow the contour of the shower base 2 If the shower base is not perpendicular to the wall use a level and draw a line around the alcove on all three...

Page 8: ...hich prevents dust particles from going into the air Always work in a well ventilated area To keep the area well ventilated open windows and use exhaust fans Always use an OSHA approved dust mask when cutting drilling or sanding Swanstone products 8 Place pieces of masking tape over the area where the saw contacts the finished surface of the panel 9 Cut the panel using a circular saw with a 60 80 ...

Page 9: ... Note Precisely scribing and cutting the panel will provide a clean 90 degree corner with no need for corner molding Flat Panel Square Tile or Subway Tile Panel 3 Place the wall panel finished side facing up on a flat surface Place pieces of masking tape over the area where the saw contacts the Swanstone panel 4 Cut the panel using a circular saw with a 60 80 tooth carbide blade or a saber saw wit...

Page 10: ...s wider than the wall take this width into consideration when scribing the panel Note Precisely scribing and cutting the panel will provide a clean 90 degree corner with no need for corner molding 3 Place the wall panel finished side facing up on a flat surface Place pieces of masking tape over the area where the saw contacts the Swanstone panel WARNING Dust Hazard When cutting or drilling the Swa...

Page 11: ...aller This temporary bonding method must hold the panel to the wall during the 24 hour curing time of the 100 clear silicone sealant The hot melt glue by itself is not sufficient to bond the panel to the wall Therefore improper or inadequate application of the hot melt glue may result in insufficient bonding of the panel to the wall Due to the weight of the panel failure to follow this recommendat...

Page 12: ...anels and walls until the silicone sets install temporary bracing after completing installation The bracing should be constructed from lengths of 2 x 4 s Failure to brace in the manner described could keep the panels from adhering resulting in personal injury as well as water damage or other damage to floors walls or other portions of your building or home IMPORTANT NOTICE To prevent scratches or ...

Page 13: ...ure to the back panel to hold it in place For corner shower wall installation use the following illustrated bracing design ATTENTION Additional bracing may be required if the Swanstone brand panel does not make full contact to the wall it is adhered to These boards need to be attached to the two outlying boards Attach this board to the wall Attach this board to the wall 5 Remove the braces after 2...

Page 14: ...using a coarse grit 60 grit sandpaper 4 Apply silicone to the edge of the soap dish Note Either clear or color matched silicone can be used for attaching the soap dish 5 Align the soap dish with the level lines and press it into place 6 Hold the soap dish securely in place and wipe off excess silicone You will want a uniform bead on both top and bottom 7 Temporarily secure the soap dish with maski...

Page 15: ...ICE Do not use oil based cleaners such as mineral spirits to clean the panels The oil in the cleaner will prevent the panel from adhering properly to the wall 4 Apply a 1 8 to 1 4 bead of silicone to the back of the corner molding in an S pattern as shown 5 Press the corner moldings into place Remove any excess silicone 6 Place at least three pieces of masking tape on each corner molding to hold i...

Page 16: ... with fiberglass reinforced polyester DO NOT use a cleaner if the label indicates it should not be used on solid surface acrylics or fiberglass reinforced polyester DO NOT use spray on cleaners that require daily use without immediately rinsing with water to stop the chemical cleaning reaction because damage will result and void the warranty Day To Day Cleanup Simply wipe the surfaces with a clean...

Page 17: ...ges made to the product by professional tradesmen or fabricators The Swan Corporation s option to repair or exchange the products under this warranty does not cover any labor or other costs of removal or installation nor shall the Swan Corporation be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or exchange of a defective product Re...

Page 18: ...Swan 18 800 325 7008 ...

Page 19: ......

Page 20: ... these Installation Instructions for future reference They provide important information on cleaning maintenance and surface repair of the Swanstone Wall Systems and Panels www swanstone com Form 193 05 16 ...

Reviews: