Product performance
Heat output
Heat Output
(kW)
Power
Consumption
(kW)
Fused
spur
Mains Cable
(m)
4.0
4.1
20A
1.5
Preparation
a) Ensure the mounting surface is capable of
supporting this heater appliance and that the
area can provide the installation clearances
shown in diagram 1.
b) If installing this heater appliance into a false
or suspended ceiling, suitable suspension chains
or rods (6 mm dia., threaded) will be required
for attachment from the top of the heater
appliance to the rigid or solid surface above
the mounting area. When using this installation
technique, it is recommended the four fixing
points at the top corners of the heater
appliance be used to minimise movement.
c) An installation point for the heater appliance
control must be selected, Controls as follows:
Wireless wall controller
The selected area must be free from moisture
and no higher than 2 metres from the floor. An
electrical cable is required from the power supply
to the control switch and from the control switch
to the heater appliance (see under Electrical
Connections).
d) Remove the fascia and fixing screws. Store
these in a safe place until required.
e) Remove the screws retaining the side panel
marked Electrical Connections and take out the
panel. Store these until required.
Installation