8 | SmithsEP.co.uk | Issue 003 - January 2021
Heat Emitter
Connect the mains electrical supply cable (3
core, single strand 2.5mm²) via a switched fused
isolator, fused at 20A to the heating appliance.
Do not energise the supply until the panels
described have been returned and secured.
The electrical supply to this product should be via
2.5mm² single strand 3 core cable via a switch
fused isolator fused at 20Amps.
1. Locate the cable gland on the products chassis
and loosen the clamping nut
2. Insert the supply cable into the cable gland
3. Feed the supply cable into the unit
4. With the supply cable inside the cable route the
cable to the terminal block
5. Insert the cable into the relevant connections
on the terminal block
E N L
Power supply
connection
Mains supply cable
(240V - 50Hz)
6. With the electrical connections made ensure
that the mains cable does not obstruct any
moving parts of the fan
7. Tighten the clamping nut on the cable gland,
once again ensure that wiring is not obstructing
moving parts inside the product
Electrical Connection