UDT-02 UHD HEVC Digital Camera Transmitter
MANUAL V1.0
65
4.6.2.3
Symbol Rate calculation
To calculate the symbol rate needed for a determined bandwidth, the next
equation must be implemented:
𝑆𝑆𝐸𝐸
=
𝐵𝐵𝐵𝐵
(1 +
𝐸𝐸𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅
)
Where:
SR
: Symbol Rate in Msymb/s
BW
: Bandwidth in MHz
Next, a table is shown as an example of the Symbol Rate values for a
determined Bandwidth of 28 MHz.
Bandwidth (MHz)
Roll-off
Symbol Rate (Msymb/s)
28
0.20
23.33
28
0.25
22.4
28
0.35
20.74
Table 4.14: Symbol Rate calculation