8-16 ELECTRICAL SYSTEM
Measure the relay coil resistance between the terminals using
the multi circuit tester. If the resistance is not within the specified
value, replace the starter relay with a new one.
#
09900-25008: Multi circuit tester set
)
Tester knob indication: Resistance (
Ω
Ω
Ω
Ω
)
&
Starter relay resistance
Standard: 3 – 5
Ω
Ω
Ω
Ω
NEUTRAL RELAY INSPECTION
• Remove the seat. (
!
7-4)
• Disconnect the neutral relay.
Apply 12 V to terminals
1
and
2
(
+
to
1
and
-
to
2
) and
check the continuity between
3
and
4
using a multi circuit
tester. If there is no continuity found, replace the neutral relay
with a new one.
#
09900-25008: Multi circuit tester set
,
Tester knob indication: Continuity set (
-
)
PARKING BRAKE SWITCH
(
!
8-33)
Summary of Contents for LT-F500F 2002
Page 1: ......
Page 36: ...2 22 PERIODIC MAINTENANCE ...
Page 105: ...ENGINE 3 63 Pull the rope and check that the ratchet is pushed out ...
Page 135: ...ENGINE 3 93 Countershaft Driveshaft ...
Page 149: ...ENGINE 3 107 Install the spark plug 09930 10121 Spark plug wrench set ...
Page 224: ...COOLING AND LUBRICATION SYSTEM 6 19 ENGINE LUBRICATION SYSTEM Oil jet ...
Page 227: ...CHASSIS 7 3 Rear carrier Rear fender Fuel tank cover Mud guard Battery holder plate Rear box ...
Page 381: ...Prepared by August 2002 Part No 99500 44050 01E Printed in Japan 384 ...
Page 382: ...Printed in Japan K3 ...