![Sutron MONITOR Operation & Maintenance Manual Download Page 54](http://html.mh-extra.com/html/sutron/monitor/monitor_operation-and-maintenance-manual_1407880054.webp)
All commands may be preceded with an !
. If they are, a concise reply meant
for machine to machine interaction is returned. Commands would be
preceded by an ! if they were sent by an Xpert or some such computer.
E.g. “MEAS” will show
M1 BARO
6.41
2007/12/12
14:55:22
“!MEAS” will show
6.41, 2007/12/12 14:55:22
NOTE:
Every setup variable can be viewed by typing its name.
E.g. “STATION NAME” will show the current name.
Every setup variable can be changed by typing its name = new value.
E.g. “STATION NAME = STURON” will set the current name to
SUTRON.
List of commands
BATTERY
Shows the current battery reading.
DIAG + 0
Shows system diagnostics, including system resets. If followed by 0, it will clear
system resets.
DOWNLOAD
See LOG
EXIT
Quits command line.
HELP
Brings up the help (lists commands).
Also try HELP SETUP and HELP LOG
HI
System replies with “Hello.”
LAST +
Shows the last measured reading of every active measurement. This command
does not make a new measurement, only shows the last results of the last
measurement. If preceded by the measurement designator (E.g. “M1 LEAS”), it
shows only one sensor.
LOG
This command is used to download the log. It can be followed by optional
parameters indicating what part of the log to download.
LOG with no parameters will download since last.
“LOG ALL” gets whole log.
“LOG X” gets X last days ("LOG 3" gets last 3 days worth of data)
“LOG timeStart” gets data since provided date
“LOG timeStart timeEnd” gets data between provided dates
time can be YYYY/MM/DD HH:MM:SS or YYYY/MM/DD or HH:MM:SS
54