03/01/16
670- 00017B
13
To avoid lift cylinder damage, the screw depth must not
exceed 7mm (0.27 in.) into the lift cylinder housing as
shown below.
•
Install each cylinder to the workstation frame using (4) - M5 screws of the
appropriate length. Suspa
®
Incorporated recommends a lift cylinder mounting
screw thread engagement of 0.196-0.275in. (5-7mm).
•
Ensure that there is enough flexible hydraulic tubing to reach each workstation leg
without putting any tension on the tubing and while maintaining the minimum
flexible tubing bend radius of 2in. (51mm). Each standard system is shipped with
hydraulic tubing cut-to-length and assembled to the unit, (2) lengths at 8.2 ft.
(2.5m), and (2) lengths at 10.2 ft. (3.1m). Custom lengths of tubing can also be
ordered.
•
Check the lift cylinder mounting screws to ensure that they are tightly secured to
the workstation. Take special care not to over tighten lift cylinder mounting
screws. Suspa
®
Incorporated recommends a lift cylinder mounting screw
tightening torque of 4.0-4.5 N-m (35-40 lb-in).
NOTICE