background image

 

 

 

 

03/01/16 

 

 

670- 00017B 

 

 

3

installation.  Do not attempt to disassemble system or system components for any reason.  
If a defective component is found, contact Suspa

®

 Incorporated for repair or replacement.   

 
USE OF TRAINED AND QUALIFIED PERSONNEL System installation, operation, 
and repair should only be done by persons having sufficient knowledge of the lift system 
and the contents of this manual.  In addition, they must have an understanding of all 
warnings and precautionary measures noted in these safety instructions.   
 
AVOID HAZARDOUS ENVIRONMENT.  Do not operate the system outside.  Do not 
expose the system to damp or wet conditions.  Avoid any chemical or corrosive 
environments.  Do not operate the system in the presence of flammable solvents, 
propellants, and/or explosive materials (i.e. gas, vapor, dust, etc.)  Avoid temperatures 
outside of the system rated operating temperature range 41

°

 to 113

°

F (5

° 

to 45

°

C).  Do 

not subject lift system components to vibration and/or impact load conditions. 
  
INSTALLATION SAFEGUARDS.  Do not use the system for any purpose other than 
its intended function.  Before operating system, make sure that the workstation has a 
minimum clearance of 2 in. (51mm) from any other object or structure to prevent 
pinching or crushing hazards.  Do not allow wall, cabinet, electrical lines, hydraulic or 
pneumatic lines, or any other fixed structures to obstruct the movement of the 
workstation during operation. 
 
KEEP CHILDREN AWAY.  It is not recommended that children operate this lift 
device.  If this device is used by or near children, close supervision is absolutely 
necessary.  
 
USE OF ACCESSORIES.  Use only spare parts and accessories authorized or supplied 
by Suspa

®

 

Incorporated.  Do not replace or replenish lift system hydraulic fluid unless the 

fluid is supplied by Suspa

®

 Incorporated. 

 

MAINTENANCE SAFEGUARDS.  Prior to performing any maintenance or service on 
the device, remove the load from all lift cylinders.  The workstation or structure that the 
lift system is attached to should be stabilized to prevent personal injury or property 
damage during maintenance or service procedures. 
 
RETRACT SYSTEM BEFORE MOVING.  To reduce the risk of property damage and 
personal injury, always retract the lift system fully before moving the equipment. 
 
UNPLUG BEFORE CLEANING.  
Retract the lift system before cleaning components.  
Clean system components with a mild soap and water-damped cloth.  Do not use 
corrosive cleaning agents or high pressure wash systems to clean lift system components. 
Make sure system is clean and dry before operating the system. 
 
SAVE THIS MANUAL FOR FUTURE REFERENCE. 

Summary of Contents for MOVOTEC MLS-00001

Page 1: ...corporated All rights reserved No part of this manual may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying recording or by any information stora...

Page 2: ...ent Placement 9 7 2 Crank Driven Pump Installation 10 7 3 Lift Cylinder Installation 11 7 4 Hydraulic Tubing Management 14 7 5 Workstation Leveling 14 8 0 Operation Instructions 16 8 1 Before Loading...

Page 3: ...abuse of this product resulting in property damage personal injury or death FAILURE TO FOLLOW THE INSTRUCTIONS IN THIS MANUAL COULD RESULT IN PROPERTY DAMAGE PERSONAL INJURY OR DEATH If you have any q...

Page 4: ...t or structure to prevent pinching or crushing hazards Do not allow wall cabinet electrical lines hydraulic or pneumatic lines or any other fixed structures to obstruct the movement of the workstation...

Page 5: ...rotated in a clockwise CW direction the leadscrew shaft rotates in the same CW direction As the crank continues to rotate in a CW direction the threaded pusherblock moves up the leadscrew in the direc...

Page 6: ...aulic tubing and into the pressure elements It is important to note that the user will feel increased resistance at the crank handle when the pump has reached its lower limit 5 0 Unpacking Instruction...

Page 7: ...ill Templates 4 D Cable Ties 8 E Mounting Clips 8 If the lift system is damaged or any component is missing please first contact Suspa Incorporated to resolve the issue before installing the system Di...

Page 8: ...2 18 58 456 17 95 MLS 00004 400 15 7 340 750 558 5 21 99 340 13 39 594 23 39 578 22 76 MLS 00005 150 5 9 454 1000 258 5 10 18 165 6 50 352 13 86 336 13 23 MLS 00006 200 7 9 454 1000 333 5 13 13 240 9...

Page 9: ...nd Y dimensions 6 3 Regulatory Information RoHS Directive 2002 95 EC Suspa Incorporated has examined all of the materials and processes utilized in the production of Movotec lift systems and has deter...

Page 10: ...he minimum hydraulic tubing bend radius of 2 in 51mm to be maintained The crank should be located near the edge of the work surface Suspa Incorporated offers other cranks and crank hardware options wh...

Page 11: ...own for ease of component placement and installation Place crank driven pump in the desired location making sure sufficient clearance exists for the crank to rotate freely beyond the work surface Mark...

Page 12: ...7 3 Lift Cylinder Installation Unwrap lift cylinders and drilling templates from bubble wrapping Dispose of bubble wrapping material in an ecologically sound manner Thoroughly clean all workstation le...

Page 13: ...l number The lift cylinder model number can be found on the product label Bolt On lift cylinder model numbers begin with CB i e CB431 Lift cylinder mounting instructions can also be found printed on t...

Page 14: ...orkstation leg without putting any tension on the tubing and while maintaining the minimum flexible tubing bend radius of 2in 51mm Each standard system is shipped with hydraulic tubing cut to length a...

Page 15: ...iled Movotec Tube Shortening Instructions If hydraulic tubing lengths are too short it is only possible to make the tubing lengths longer by replacing the line using a Movotec Refill Kit part number D...

Page 16: ...the system take special care not to drop the workstation onto the lift cylinders Place a level on the top of the work surface Unthread glide s from the lift cylinder s as needed to achieve a level wo...

Page 17: ...height adjustment The Movotec lift system is single acting and will require a minimum load of 35 lb 15 9 kg per cylinder for even lift system retraction 8 1 Before Loading the Workstation Check all h...

Page 18: ...r any questions exist before operation system information can be found using the product labels located on the side of the pump reference photographs below Movotec pump part number and description Mov...

Page 19: ...nk in the CW direction until the workstation has reached the desired height or the upper limit is reached 8 3 System Retraction Cycle Rotate crank in the counter clockwise CCW direction Continue rotat...

Page 20: ...sily be stowed inside the crank body Pull crank grip outward until crank mechanism begins to fold Note Suspa Inc offers additional crank options Please see the additional offerings at https shop suspa...

Page 21: ...r replacement pump Problem Crank is difficult to turn Possible Causes Recommended Solutions Upper or Lower Limit Reached Stop rotating crank Workstation movement is obstructed by fixed object s Provid...

Page 22: ...Conditions Overload conditions should be promptly corrected to prevent premature wear of mechanical components This will also prevent overheating and premature failure of electrical components 10 2 Co...

Page 23: ...be considered defective if Suspa Incorporated finds that it is defective in materials or workmanship and if the defect materially impairs the value of the goods to the Buyer except that if the Buyer...

Page 24: ...ny optional accessories for customizing Movotec Crank Driven Bolt On Lift Systems which include Lift cylinder mounting brackets Special folding cranks Hydraulic tube shortening instructions System ref...

Reviews: