21
REFRIGERATION SYSTEM AND TEMPERATURE ADJUSTMENT
REFRIGERATION SYSTEM
•
The refrigeration system is a hermetically sealed system which uses
R134-A refrigerant
.
•
If recharging of the system is required, the refrigeration technician should refer to the
A. C. Dispensing Equipment Inc. Machine Identification Label located on the left side of the
dispenser for details on the quantity of refrigerant used.
•
The condenser is located at the rear of the dispenser behind the back panel.
•
The evaporator is incorporated within the stainless steel walls of the refrigerated product
compartment, i.e. cold-wall evaporation system.
•
The compressor is located below the refrigerated product compartment and is accessible
through the back panel.
•
The ambient temperature range for dispenser operation is 50 °F to 90 °F (10 °C to 32 °C).
Refrigerated
Product
Compartment
Condenser
Fan
Filter/Dryer
Compressor