3815Y1 SureFire PumpRight for Raven RCM
5
Revised 12/04/2019
PR40 & D250 Electromagnetic Flowmeter Kit
2.6
-
53 GPM Item Number 500
-
02
-
2080
Kits include flowmeter, adapter harness, mounting bracket, hose barb fittings & hose
clamps.
Flowmeter Model
(black meter with orange label)
JDRC 2000 Flow
Calibration
FPT Size
Hose Barb
In kit
2.6
—
53
GPM
2000
1
-
1/4”
1
-
1/2”
1.3
—
26
GPM
2000
1”
1”
B
Components
Liquid
Earlier model flowmeters (meters with white labels with black text) have different calibration numbers. See the
documentation for those meters to find the calibration numbers.
Amp SuperSeal 3
-
pin connector
Use adapter 201
-
17842
to connect to 3
-
pin MP harness
-
Before doing any arc welding on the implement, unplug the cable to the flowmeter, or damage to the
flowmeter may result.
-
Do not power wash the flowmeter. High pressure spray directed at the back edge of the face plate or at
the wire connector may allow water into the flowmeter electronics.
Mounting Bracket,
400
-
3335Y1 (QTY 2)
(used for PR40 and D250
Pump only)
Troubleshooting Tip
:
Remove red guard to
reach pins. Be care-
ful so you don
’
t break
red side keepers.
1 2 3
3
-
pin AMP SuperSeal
1
–
Ground
2
–
12V Power
3
–
Signal
Power to Ground should be 12 volts.
Signal to Ground should be 4.5 to 5 volts
Do Tap Test between Signal and Ground to test harnessing.
3
-
pin MP Tower
A
-
Signal B
-
12V Power C
-
Ground
Additional Tip:
If flowmeter is not
reading and the har-
nessing has checked
out OK with voltage
readings and tap test,
try cleaning the inside
tube of flowmeter with
warm soapy water
and a soft brush.
Sometimes, a film
builds up on the elec-
trodes.
SureFire
Ag