3815Y1 SureFire PumpRight for Raven RCM
4
Revised 12/04/2019
PR17 & PR30 Electromagnetic Flowmeter Kits
0.13
-
2.6 GPM Item Number 500
-
02
-
2082 (PR17)
0.3
-
5 GPM Item Number 500
-
02
-
2085 (PR17)
0.6
-
13 GPM
Item Number 500
-
02
-
2090 (PR17 & PR30)
1.3
-
26 GPM
Item Number 500
-
02
-
2095 (PR30)
Kits include flowmeter, adapter harness, mounting bracket, hose barb fittings & hose clamps.
Flowmeter Model
(black meter with orange label)
JD GRC Flow
Calibration
FPT Size
Hose Barb
In kit
0.13
-
2.6 GPM
3000
3/4”
1”
0.3
-
5 GPM
3000
3/4”
1”
0.6
-
13 GPM
2000
3/4”
1”
1.3
-
26 GPM
2000
1”
1”
B
Components
Liquid
Earlier model flowmeters (meters with white labels with black text) have different calibration numbers. See the
documentation for those meters to find the calibration numbers.
-
Before doing any arc welding on the implement, unplug the cable to the flowmeter, or damage to the
flowmeter may result.
-
Do not power wash the flowmeter. High pressure spray directed at the back edge of the face plate or at
the wire connector may allow water into the flowmeter electronics.
Amp SuperSeal 3
-
pin connector
Use adapter 201
-
17842
to connect to 3
-
pin MP harness
Mounting Bracket,
400
-
3826Y1 (QTY 1)
(not used for PR40 and
D250 Pump)
Mounting Bracket,
410
-
4015Y1 (QTY 1)
(not used for PR40 and
D250 Pump)
Troubleshooting Tip
:
3
-
pin MP Tower A
-
Signal B
-
12V Power C
-
Ground
(See the next page for more flowmeter tips)
3
-
pin AMP SuperSeal
1
–
Ground
2
–
12V Power
3
–
Signal
Remove red guard to reach pins. Be careful so you don
’
t break red side keepers.
1 2 3
Electromagnetic flowmeters are superior to traditional turbine flowmeters in two basic ways. First, they
have no moving parts. There are no wear items or potential for contaminants to jam a spinning turbine.
Second, electromagnetic flowmeters detect the flow by electrically measuring the velocity of the liquid,
which makes them independent of viscosity or density of the fluid measured. They are extremely accurate
using the standard calibration number.
SureFire still recommends you perform a catch test to verify the
system is properly installed and configured.