Safety Remarks
Reverse Osmosis is a separation process that uses pressure to force
water through a semi-permeable membrane while retaining other
substances on the other side – it's a reverse process of what naturally
takes place in all living cells.
The membrane stops 96-99% of organic
and non-organic contaminants, bacteria and viruses.
Semi-
permeable membrane consists of many layers winded up on perforated
core. Contaminated water enters the membrane element with pressure,
forcing water molecules to pass through the microscopic membrane
pores, while flushing out contaminants to a drain.
Cross-section of membrane element
2. Reverse Osmosis water filtration method
ATTENTION! Do not use the system with biologically contaminated water and of unknown origin.
The filtration system should only be installed by a trained technician. Use only genuine
SUPREME
replacement parts and accessories.
Following this manual thoroughly will guarantee:
- breakdown free use,
- honoring product warranty.
1) Read carefully this Instruction Manual before starting system
installation.
2) Check if all elements needed for the installation are included with the
system. (refer to point 5 “Box Content”).
3) Remember to conduct system flushing right after the installation
process is completed and each time after filter cartridge replacement
(including sediment and in-line filter cartridges or RO membrane
element) as well as after longer periods of time (for instance vacation
periods) when the system has not been used. Next, leave the system
idle for 5-6 hours allowing the filtration environment to set in.
4) Before disconnecting any tubing: remove safety clips from quick
connectors and next press the connector's flange and pull the tubing
out.
5) During disconnecting and connecting of tubing be sure not to break it
(correctly installed tubing should be inserted 1.5 cm inside of quick
connector).
6) Do not move or rotate quick connectors which are installed in
membrane housing during disconnecting or connection of tubing.
7) Secure quick connector with safety clip after tubing has been inserted.
8) For sealing plastic components use only Teflon tape!
9) Do not use strong detergents when washing filter housings. Rinse filter
housings with clean water each time before installing new filter
cartridges.
10) When installing new in-line filter cartridge, remember about inserting it
according to the direction of water flow (refer to direction arrow
displayed on each filter cartridge).
11) Wash your hands thoroughly before and after filter cartridge or
membrane element replacements.
12) Remove RO membrane out of packaging only few moments before its
installation.
13) In case system is leaking, disconnect it from its water supply.
14) 4-way valve needs to be cleaned each time after cartridge replacement
is completed (or at least every 6 months).
15
)
System disinfection should be conducted ones a year. ATTENTION!
Do not use running water for that purpose since it can be contaminated.
16) Water that will undergo Reverse Osmosis process must meet certain
conditions (refer to point 4).
17) In all cases of product returns, the system must be returned in its
original packaging – otherwise the return will not be accepted.
18) Manufacturer is not responsible for any damages resulted from the use
of this product if used for other purposes than filtration of potable water.
19)
The producer does not hold any responsibility for printing errors.
20)
We reserve the right to introduce change or amendments of the
provided technical
informations at any time and without the necessity of
a prior
announcement.
Use only genuine
SUPREME
replacement parts, filter cartridges and
membrane elements. In case of use of other manufacturers' parts, is not
responsible for any damages caused in the course of product use of.
WATER INLET
SEMI-PERMEABLE LAYER
SEAL
PERFORATED CORE
FILTERED WATER
OUTLET
REJECTION
OUTSIDE PROTECTIVE LAYER
EN
SUPREME-RO5 dimensions (H x W x L)............................................................................................................................................400 mm x 140 mm x 390 mm
SUPREME-RO6 dimensions (H x W x L)............................................................................................................................................400 mm x 140 mm x 450 mm
SUPREME-RO6-P dimensions (H x W x L).........................................................................................................................................500 mm x 200 mm x 390 mm
SUPREME-RO7 dimensions (H x W x L)............................................................................................................................................400 mm x 140 mm x 450 mm
RO tank dimensions (H x Diameter) ...................................................................................................................................................................380 mm x 280 mm
O
O
Work. temperature.................................................................................................................................................................................................od 2 C do 45 C
Work. pressure.........................................................................................................................................................................................................2,8 bar - 6 bar
Efficiency*........................................................................................................................................................................................................................280l/24h
Inlet size..................................................................................................................................................................................................................................3/8"
RO tank capacity**............................................................................................................................................................................................................12 liters
3.
System parameters
* nominal capacity
** nominal capacity
supreme