background image

Safety Remarks

Reverse  Osmosis  is  a  separation  process  that  uses  pressure  to  force 
water  through  a  semi-permeable  membrane  while  retaining  other 
substances  on  the  other  side  –  it's  a  reverse  process  of  what  naturally 
takes place in all living cells. 

The membrane stops 96-99% of organic 

and  non-organic  contaminants,  bacteria  and  viruses. 

Semi-

permeable membrane consists of many layers winded up on perforated 
core. Contaminated water enters the membrane element with pressure, 
forcing  water  molecules  to  pass  through  the  microscopic  membrane 
pores, while flushing out contaminants to a drain.

Cross-section of membrane element

2. Reverse Osmosis water filtration method

ATTENTION! Do not use the system with biologically contaminated water and of unknown origin.

The filtration system should only be installed by a trained technician. Use only genuine 

SUPREME

 replacement parts and accessories.

Following this manual thoroughly will guarantee:
- breakdown free use,
- honoring product warranty.

1)   Read  carefully  this  Instruction  Manual  before  starting  system   
 

installation.

2)   Check if all elements needed for the installation are included with the   
 

system. (refer to point 5 “Box Content”).

3)   Remember  to  conduct  system  flushing  right  after  the  installation   
 

process is completed and each time after filter cartridge replacement   

 

(including  sediment  and  in-line  filter  cartridges  or  RO  membrane   

 

element) as well as after longer periods of time (for instance vacation   

 

periods) when the system has not been used. Next, leave the system   

 

idle for 5-6 hours allowing the filtration environment to set in.

4)   Before  disconnecting  any  tubing:  remove  safety  clips  from  quick   
 

connectors and next press the connector's flange and pull the tubing   

 

out.

5)   During disconnecting and connecting of tubing be sure not to break it   
 

(correctly  installed  tubing  should  be  inserted  1.5  cm  inside  of  quick   

 

connector).

6)   Do  not  move  or  rotate  quick  connectors  which  are  installed  in   
 

membrane housing during disconnecting or connection of tubing. 

7)   Secure quick connector with safety clip after tubing has been inserted.
8)   For sealing plastic components use only Teflon tape!
9)   Do not use strong detergents when washing filter housings. Rinse filter 
 

housings  with  clean  water  each  time  before  installing  new  filter   

 

cartridges.

10)  When installing new in-line filter cartridge, remember about inserting it 
 

according  to  the  direction  of  water  flow  (refer  to  direction  arrow   

 

displayed on each filter cartridge).

11)  Wash  your  hands  thoroughly  before  and  after  filter  cartridge  or   
 

membrane element replacements.

12)   Remove RO membrane out of packaging only few moments before its 
 

installation.

13)   In case system is leaking, disconnect it from its water supply.
14)   4-way valve needs to be cleaned each time after cartridge replacement 
 

is completed (or at least every 6 months).

15

  System disinfection should be conducted ones a year. ATTENTION!       

 

Do not use running water for that purpose since it can be contaminated.

16)   Water that will undergo Reverse Osmosis process must meet certain 
 

conditions (refer to point 4).

17)   In  all  cases  of  product  returns,  the  system  must  be  returned  in  its   
 

original packaging – otherwise the return will not be accepted.

18)   Manufacturer is not responsible for any damages resulted from the use 
 

of this product if used for other purposes than filtration of potable water.

19)  

The producer does not hold any responsibility for printing errors.

 

20)

  

We  reserve  the  right  to  introduce  change  or  amendments  of  the 

 

 

provided technical

 

informations at any time and without the necessity of 

 

a prior

 

announcement.

Use  only  genuine 

SUPREME

  replacement  parts,  filter  cartridges  and 

membrane elements. In case of use of other manufacturers' parts, is not 
responsible for any damages caused in the course of product use of.

WATER INLET

SEMI-PERMEABLE LAYER

SEAL

PERFORATED CORE

FILTERED WATER 

OUTLET 

REJECTION

OUTSIDE PROTECTIVE LAYER

EN

SUPREME-RO5 dimensions (H x W x L)............................................................................................................................................400 mm x 140 mm x 390 mm
SUPREME-RO6 dimensions (H x W x L)............................................................................................................................................400 mm x 140 mm x 450 mm
SUPREME-RO6-P dimensions (H x W x L).........................................................................................................................................500 mm x 200 mm x 390 mm
SUPREME-RO7 dimensions (H x W x L)............................................................................................................................................400 mm x 140 mm x 450 mm
RO tank dimensions (H x Diameter) ...................................................................................................................................................................380 mm x 280 mm 

O

O

Work. temperature.................................................................................................................................................................................................od 2 C do 45 C 
Work. pressure.........................................................................................................................................................................................................2,8 bar - 6 bar
Efficiency*........................................................................................................................................................................................................................280l/24h
Inlet size..................................................................................................................................................................................................................................3/8"
RO tank capacity**............................................................................................................................................................................................................12 liters

3. 

System parameters

*  nominal capacity
** nominal capacity

supreme 

best water solutions

Summary of Contents for RO5 PREMIUM

Page 1: ...Installation Manual Instrukcja monta u...

Page 2: ...plastic components use onlyTeflon tape 9 Do not use strong detergents when washing filter housings Rinse filter housings with clean water each time before installing new filter cartridges 10 When inst...

Page 3: ...valve for water tank Tubings Shut off valve Clamp Required water pH 2 pH 11 pH 3 Max general water hardness 400 ppm mg l Max alkalinity 8 mval l 3 Fe Mg contant 0 05 ppm mg l 1 Max SDI index SDI 5 2 3...

Page 4: ...Connecting elbow connector with filter cartridge 1 Screw the elbow connector back to new filter cartridge NOTE Do NOT remove elbow connector after the installation has been started Stopping and removi...

Page 5: ...rocedures filtered and conditioned water may be consumed WARNING Filter cartridges are not subject to complaint at the time of after opening protective packaging after first use of filter cartridges A...

Page 6: ...13 14 6 15 16 4 17 18 SUPREME SUPREME RO5 dimensions 400 x 140 x 390 SUPREME RO6 dimensions 400 x 140 x 450 SUPREME RO6 P dimensions 500 x 200 x 390 SUPREME RO7 dimensions 400 x 140 x 450 380 x 280 2...

Page 7: ...Disolved Solids 3 ppm 4 5 20 S PP20 1 S L CARB 2 S L CARB and S L MIN 3 S L CARB S L MIN AIFIR2000 4 S L CARB S L MIN PUMP 1 x 2 x 5 S PP5 S BL 3 8 x 3 8 x 1 4 5 t 6 12 1 SUPREME RO5 2 SUPREME RO6 3 S...

Page 8: ...JG John Guest QC Quick connector 1 1 2 2 3 3 1 1 5 4 2 5 1 2 3 4 5 7 1 a 1 1 2 2 3 3 4 4 5 5 1 6 1 2 3 4 5 6 8 1 12 2 2 3 3 4 4 5 6 7 5 11 10 9 8 supreme best water solutions 10 11 1 2 3 4 5 6 7 8 9 F...

Page 9: ...5 c 9 7 8 x 2 1 2 25 c x 6 5 c 9 7 8 x 2 1 2 25 c x 6 5 c 10 8 x 2 27 5 c x 5 c 3 6 3 6 3 6 6 12 6 12 3 6 96 99 60 10 x 2 25 c x 5 08 c 10 x 2 25 c x 5 08 c 11 9 x 1 8 30 c x 4 5 c AIFIR2000 2 pH S P...

Page 10: ...talowaniu w yka w szybkoz czce nale y zabezpieczy miejsce po czenia klipsem 8 Do uszczelniania gwint w wykonanych z tworzywa sztucznego nale y u ywa wy cznie ta my teflonowej Do uszczelniania nie mo n...

Page 11: ...ad z w kniny polipropylenowej 20 mik S PP20 Komponent wraz z wk adami 1 S L CARB Komponent wraz z wk adami 2 S L CARB and S L MIN Komponent wraz z wk adami 3 S L CARB S L MIN AIFIR2000 Komponent wraz...

Page 12: ...zki we wk adzie 1 Wkr ci kolanko do nowego wk adu Uwaga podczas wkr cania kolanka nie cofa kolanka Cofni cie wkr canego elementu mo e doprowadzi do rozszczelnienia po czenia oraz wycieku wody Rys 6 Ry...

Page 13: ...i zanieczyszczenia zawarte w wodzie o wielko ci ziaren 20 mikron w i wi ksze Wk ad wykonany z w kniny polipropylenowej znakomicie poprawia parametry organoleptyczne wody S PP5 Wk ad mechaniczny do zi...

Page 14: ...d water Uj cie wody czystej Tank Zbiornik Faucet Wylewka I 3 J 4 1 5 2 6 Filter housing with carbon block filter cartridge S BL S BL Korpus z wk adem w glowym S BL Filter housing with 20 micron sedime...

Page 15: ...ilter cartridge S L CARB S L CARB Wk ad szlifuj cy S L CARB Flow restrictor Ogranicznik przep ywu Valve for water storage tank Zaw r zbiornika Water outlet filtered water Uj cie wody czystej Rejection...

Page 16: ...s z membran osmotyczn 4 way valve Zaw r czterodro ny Water conditioning in line filter cartridge S L CARB S L CARB Wk ad szlifuj cy S L CARB Water mineralizing in line filter cartridge S L MIN S L MIN...

Page 17: ...5 Filter housing with RO membrane element Korpus z membran osmotyczn 4 way valve Zaw r czterodro ny Water conditioning in line filter cartridge S L CARB S L CARB Wk ad szlifuj cy S L CARB Flow restric...

Reviews: