7.1. Faucet installation

NOTE: To seal the threaded connections, use teflon tape during the 
installation.  This  doesn't  apply  to  threads  for  plastic  and  faucet 
nuts.

1) To install the faucet (fig.) drill two 12 mm holes in the countertop or 
  the sink (in case of enamelled sinks, the manufacturers  
  recommend drilling the holes in the support structure of the sink). 
  The holes should be 18 mm apart.
2) Put the metal washer 2 and the rubber seal 3 on the threaded 
  faucet connectors.
3) Mount the faucet in the previously drilled holes.
4) From the underside of the countertop, put washers 4, 5 on the 
    connectors, and tighten with nuts 7.
5) The water tubing needs to be connected to the faucet. To do this, 
  put metal nuts (9) and plastic clamps (8) on the tubing, and push 
  inserts (7) into the tubing. 
6) Push the tubing (all the way) inside the faucet connectors and hand 
    tighten them with the nuts placed earlier on the tubing.

9. Filtration Cartridges

Dimensions

S-L-CARB

 Coconut shell carbon filter cartridge. Improves taste and smell of water.

S-L-MIN 

Water mineralizing cartridg     enriches water with elements that are necessary for human body, 

such as: calcium, magnesium, potassium and sodium.

9 7/8” x 2 1/2”

(25 cm x 6,5 cm)

9 7/8” x 2 1/2”

(25 cm x 6,5 cm)

9 7/8” x 2 1/2”

(25 cm x 6,5 cm)

10,8” x 2”

(27,5 cm x 5 cm)

Cartridge Type

Description / Filtration Stage

Longevity*

3 - 6 months

3 - 6 months

3 - 6 months

6 - 12 months

6 - 12 months

6 - 12 months

* Depends on amounts of filtered water, its quality and level of contamination.

Before the first use of system and after each cartridge replacement, the 
system should be flushed with water for at least 5 minutes. Next, allow 
the system to standby for 5-6 hours to activate its filtration ability. After 
these procedures, filtered and conditioned water may be consumed. 

WARNING!  Filter  cartridges  are  not  subject  to  complaint  at  the 
time of:

- after opening protective packaging,
- after first use of filter cartridges.

ATTENTION!  Before  first  time  use  and  each  time  after  replacing  RO 
membranes element, proceed with backwash procedure.

Wait 60 minutes till water tank is full with water, next open system's content

 

faucet and drain entire water from the tank.

ATTENTION! Do not drink this water.
After this process is completed, leave the system idle for 5 to 6 hours to 
activate filtration readiness. Next fill system's tank with newly filtered 
water one more time and again open system's faucet and drain entire 
water from the tank. ATTENTION! Do not drink this water.

S-PP20

 Sediment filter for cold water. Used to filter potable and utility water - stops sand, rust particles, 

suspended  solids  and  contaminants  contained  in  water  with  grain  size  of  20  microns  and  more.  A 
polypropylene spun cartridge improves organoleptic parameters of water.

S-PP5

 Sediment filter for cold water. Used to filter potable and utility water - stops sand, rust particles, 

suspended  solids  and  contaminants  contained  in  water  with  grain  size  of  5  microns  and  more.  A 
polypropylene spun cartridge improves organoleptic parameters of water.

S-BL

 Fertilizing cartridge. Contains the sitered carbon with high absorptive abilities of chlorine and organic 

substances contained in water. The sintered carbon has a large active surface and high efficiency of water 

filtration. 

AIFIR2000 

2” Ionizer 

AIFIR2000

 regulates body's pH factor and helps to detoxify body (ionized water is an 

excellent detoxifying agent).

Reverse  osmosis  membrane  element  removes  96%  -  99%  of  all  contaminants  (including  bacteria  and 
viruses).

up to 

60 months

10” x 2” 

(25 cm x 5,08 cm)

10” x 2” 

(25 cm x 5,08 cm)

11,9” x 1,8”

(30 cm x 4,5 cm)

System backwash

supreme 

best water solutions

3

4
5

6
7
8
9

12

18

Summary of Contents for RO5 PREMIUM

Page 1: ...Installation Manual Instrukcja monta u...

Page 2: ...plastic components use onlyTeflon tape 9 Do not use strong detergents when washing filter housings Rinse filter housings with clean water each time before installing new filter cartridges 10 When inst...

Page 3: ...valve for water tank Tubings Shut off valve Clamp Required water pH 2 pH 11 pH 3 Max general water hardness 400 ppm mg l Max alkalinity 8 mval l 3 Fe Mg contant 0 05 ppm mg l 1 Max SDI index SDI 5 2 3...

Page 4: ...Connecting elbow connector with filter cartridge 1 Screw the elbow connector back to new filter cartridge NOTE Do NOT remove elbow connector after the installation has been started Stopping and removi...

Page 5: ...rocedures filtered and conditioned water may be consumed WARNING Filter cartridges are not subject to complaint at the time of after opening protective packaging after first use of filter cartridges A...

Page 6: ...13 14 6 15 16 4 17 18 SUPREME SUPREME RO5 dimensions 400 x 140 x 390 SUPREME RO6 dimensions 400 x 140 x 450 SUPREME RO6 P dimensions 500 x 200 x 390 SUPREME RO7 dimensions 400 x 140 x 450 380 x 280 2...

Page 7: ...Disolved Solids 3 ppm 4 5 20 S PP20 1 S L CARB 2 S L CARB and S L MIN 3 S L CARB S L MIN AIFIR2000 4 S L CARB S L MIN PUMP 1 x 2 x 5 S PP5 S BL 3 8 x 3 8 x 1 4 5 t 6 12 1 SUPREME RO5 2 SUPREME RO6 3 S...

Page 8: ...JG John Guest QC Quick connector 1 1 2 2 3 3 1 1 5 4 2 5 1 2 3 4 5 7 1 a 1 1 2 2 3 3 4 4 5 5 1 6 1 2 3 4 5 6 8 1 12 2 2 3 3 4 4 5 6 7 5 11 10 9 8 supreme best water solutions 10 11 1 2 3 4 5 6 7 8 9 F...

Page 9: ...5 c 9 7 8 x 2 1 2 25 c x 6 5 c 9 7 8 x 2 1 2 25 c x 6 5 c 10 8 x 2 27 5 c x 5 c 3 6 3 6 3 6 6 12 6 12 3 6 96 99 60 10 x 2 25 c x 5 08 c 10 x 2 25 c x 5 08 c 11 9 x 1 8 30 c x 4 5 c AIFIR2000 2 pH S P...

Page 10: ...talowaniu w yka w szybkoz czce nale y zabezpieczy miejsce po czenia klipsem 8 Do uszczelniania gwint w wykonanych z tworzywa sztucznego nale y u ywa wy cznie ta my teflonowej Do uszczelniania nie mo n...

Page 11: ...ad z w kniny polipropylenowej 20 mik S PP20 Komponent wraz z wk adami 1 S L CARB Komponent wraz z wk adami 2 S L CARB and S L MIN Komponent wraz z wk adami 3 S L CARB S L MIN AIFIR2000 Komponent wraz...

Page 12: ...zki we wk adzie 1 Wkr ci kolanko do nowego wk adu Uwaga podczas wkr cania kolanka nie cofa kolanka Cofni cie wkr canego elementu mo e doprowadzi do rozszczelnienia po czenia oraz wycieku wody Rys 6 Ry...

Page 13: ...i zanieczyszczenia zawarte w wodzie o wielko ci ziaren 20 mikron w i wi ksze Wk ad wykonany z w kniny polipropylenowej znakomicie poprawia parametry organoleptyczne wody S PP5 Wk ad mechaniczny do zi...

Page 14: ...d water Uj cie wody czystej Tank Zbiornik Faucet Wylewka I 3 J 4 1 5 2 6 Filter housing with carbon block filter cartridge S BL S BL Korpus z wk adem w glowym S BL Filter housing with 20 micron sedime...

Page 15: ...ilter cartridge S L CARB S L CARB Wk ad szlifuj cy S L CARB Flow restrictor Ogranicznik przep ywu Valve for water storage tank Zaw r zbiornika Water outlet filtered water Uj cie wody czystej Rejection...

Page 16: ...s z membran osmotyczn 4 way valve Zaw r czterodro ny Water conditioning in line filter cartridge S L CARB S L CARB Wk ad szlifuj cy S L CARB Water mineralizing in line filter cartridge S L MIN S L MIN...

Page 17: ...5 Filter housing with RO membrane element Korpus z membran osmotyczn 4 way valve Zaw r czterodro ny Water conditioning in line filter cartridge S L CARB S L CARB Wk ad szlifuj cy S L CARB Flow restric...

Reviews: