background image

14

NOTE: 

After removing limescale, test on an isolated area to ensure that all debris has been

removed from the unit before resuming use. 

CAUTION:
DO NOT LEAVE THE STEAMER UNATTENDED DURING LIMESCALE REMOVAL AND/OR WHILE
IN USE. 

Cleaning Steamer Attachments that are Blocked:

If you live in an area that has a high mineral content in the tap water you may notice that less
steam comes out from certain accessories. This could be caused by mineral buildup inside the
accessory nozzle tips. To clean, first detach the Hand-Held Steamer from the Mop Body as per
the previous instructions. Make sure that the unit is not plugged in. Fill the water tank with a
1/3 vinegar - 2/3 water solution and attach each affected accessory to the unit one at a time.
Plug unit in and wait for the green Ready To Use indicator light (20) to come on. Press the
ON/OFF Switch (19) (once only - Hand-Held Steamer will emit continuous steam until switch is
pressed again to turn unit off). Flush the vinegar/water solution through the attachment(s)
continuously to remove deposits. Once the steam is emitted smoothly press the ON/OFF Switch
again to turn unit off.

CAUTION:
It is preferable to perform these cleaning procedures in a well ventilated and protected
area. 

Summary of Contents for SteamTek 3

Page 1: ...NG INSTRUCTIONS IMPORTANT SAFETY INFORMATION USER S GUIDE Please read all the instructions carefully prior to using the SteamTek3 Mop for the first time Keep this manual in a safe place for future ref...

Page 2: ...izes hard floor surfaces carpets and now features a detachable hand held steamer for tough to reach areas even fabric The powerful SteamTek3 releases 1500W of high pressure steam at 90 100 C 194 212 F...

Page 3: ...corners and keep away from heaters and heated surfaces 11 DO NOT use the SteamTek3 Mop or handle the plug with wet hands 12 DO NOT operate while barefoot 13 EXERCISE CAUTION when using the SteamTek3...

Page 4: ...concerning use of the appliance by a person responsible for their safety THE STEAMTEK3 IS INTENDED FOR HOUSEHOLD USE ONLY Commercial industrial use of this unit will void the manufacturer s warranty...

Page 5: ...tachable Hand held Steamer Body 8 Mop Body 9 Small Screw 10 Short Jet Nozzle 11 Hand held Steamer Lock 12 Hand held Steamer Release Tab 13 Swivel Joint 14 Carpet Glider 15 Cord Holder 16 ON OFF Mop Tr...

Page 6: ...Illust 3 Illust 1 Illust 2 Illust 3 Illust 4 Illust 7 Illust 8 ASSEMBLY Illust 6 Illust 5 3 Fix the Screw 9 on the Mop Head with a Philips screwdriver until tight Illust 4 4 Re attach the Hand Held St...

Page 7: ...abrasions or that is otherwise damaged as streaking and scratching of floor surfaces could occur NOTE DO NOT OPERATE UNIT WITHOUT THE PAD IN PLACE The Microfiber pads 1 are machine washable in warm w...

Page 8: ...er Block the valve hole on the water tank with a finger to prevent water from dripping from tank before re attaching to the Hand Held Steamer body Illust 20 6 Re attach the tank to the Hand held Steam...

Page 9: ...n 15 seconds as this could cause a build up of pale residue If this happens the residue can be removed by using a decalcifying product or with a few drops of vinegar NOTE Use a cloth to wipe off resid...

Page 10: ...fabric cleaning attachment to remove wrinkles from NOTE To remove or replace attachments rotate them counter clockwise and pull out Illust 24 Illust 25 clothes curtains fabric upholsteries and more OP...

Page 11: ...ooms etc hold the Hand Held Steamer over the area for 15 seconds maximum WARNING DO NOT USE THE STEAMER ON HEAT STEAM SENSITIVE SURFACES The powerful force of the steam could adversely affect certain...

Page 12: ...Illust 39 Illust 38 Scoop Nozzle E Illust 33 For use on hard surfaces Jet Nozzle F Illust 34 For use in corners and edges Extension Hose G Illust 35 For easier accessibility and maneuverability in ha...

Page 13: ...d to the Hand Held Steamer directly or can be connected to the Extension Hose G as desired Window Cleaning Kit A To use attach to the Extension Hose G or directly to the Hand Held Steamer We recommend...

Page 14: ...water from the water tank 6 prior to storage 4 Let any water due to condensation drain from the steam nozzle prior to storage 5 Wrap Power Cord 22 around Cord Holder 15 to store 6 Wipe all surfaces of...

Page 15: ...disconnected from the power outlet before performing any maintenance 2 Remove the Hand Held Steamer from the main mop body and the adapter following the instructions Illust 51 3 Use any suitable objec...

Page 16: ...nd Held Steamer from the Mop Body as per the previous instructions Make sure that the unit is not plugged in Fill the water tank with a 1 3 vinegar 2 3 water solution and attach each affected accessor...

Page 17: ...r tank is empty The Steam Nozzle is blocked The copper ball in the water tank does not reach the water Limescale deposit SOLUTION Fill Water Tank Remove Mop Head and clean the nozzle Gently rock the m...

Page 18: ...Hold the hose vertically and allow water to drain out PROBLEM The cleaning cloth becomes wet POSSIBLE CAUSE The cloth has been saturated with water SOLUTION Remove wet cloth and replace with a dry one...