Chapter 6: Advanced Chassis Setup
6-9
6-5 Power
Supply
The SuperServer 6027B-TLF has a single 650 watt power supply. This power supply
module has an auto-switching capability, which enables it to automatically sense
and operate at a 100V to 240V input voltage.
Power Supply Failure
If the power supply fails, the system will shut down and you will need to replace
the power supply unit. Replacement units can be ordered directly from Supermicro.
See contact information in Chapter 1.
Removing/Replacing the Power Supply
Replace the failed power supply module with the same model, which can be ordered
directly from Supermicro (see Contact Information in the Preface).
1. First shut down the system, then unplug the AC power cord from the power
supply module.
2. Remove the chassis cover by pressing the two release buttons on the top of
the chassis (near the front) then push the chassis top rearward about one
inch and lift it off.
3. To remove the failed power supply module, remove the screws that secure its
sides to the bottom of the chassis and pull the module straight out.
4. Replace the failed module with another power supply unit.
5. Insert the new power supply module into the power bay until fully seated.
6. Secure the power supply with the screws you removed previously and
fi
nish
by plugging in the AC power cord.
Summary of Contents for SUPERSERVER 6027B-TLF
Page 1: ...SUPERSERVER 6027B TLF SUPER USER S MANUAL 1 0...
Page 5: ...v Preface Notes...
Page 14: ...1 6 SUPERSERVER 6027B TLF User s Manual Notes...
Page 22: ...2 8 SUPERSERVER 6027B TLF Manual Notes...
Page 26: ...SUPERSERVER 6027B TLF User s Manual 3 4 Notes...
Page 66: ...6 10 SUPERSERVER 6027B TLF User s Manual Notes...
Page 100: ...7 34 SUPERSERVER 6027B TLF User s Manual Notes...
Page 102: ...A 2 SUPERSERVER 6027B TLF User s Manual Notes...
Page 106: ...B 4 SUPERSERVER 6027B TLF User s Manual Notes...