6-4 Power
Supply
The SuperServer 6017R-N3RF4+/6017R-N3RFT+ has a 700 watt redundant power
supply consisting of two power modules. Each power supply module has an auto-
switching capability, which enables it to automatically sense and operate at a 100V
- 240V input voltage.
Power Supply Failure
If either of the two power supply modules fail, the other module will take the full load
and allow the system to continue operation without interruption. The PWR Fail LED
will illuminate and remain on until the failed unit has been replaced. Replacement
units can be ordered directly from Supermicro (part number PWS-703-P-1R). The
power supply units have a hot-swap capability, meaning you can replace the failed
unit without powering down the system.
Removing the Power Supply
First unplug the AC power cord from the failed power supply module.
1. Depress the locking tab on the power supply module.
2. Use the handle to pull it straight out with the rounded handle (see Fig. 6-5).
Installing a New Power Supply
1. Replace the failed hot-swap unit with another identical power supply unit.
2. Push the new power supply unit into the power bay until you hear a click.
3. Secure the locking tab on the unit.
4. Finish by plugging the AC power cord back into the unit.
Summary of Contents for SUPERSERVER 6017R-N3RF4+
Page 1: ...SUPERSERVER 6017R N3RF4 6017R N3RFT SUPER USER S MANUAL 1 0a...
Page 5: ...v Preface Notes...
Page 14: ...1 6 SUPERSERVER 6017R N3RF4 6017R N3RFT User s Manual Notes...
Page 22: ...2 8 SUPERSERVER 6017R N3RF4 6017R N3RFT User s Manual Notes...
Page 26: ...3 4 SUPERSERVER 6017R N3RF4 6017R N3RFT User s Manual Notes...
Page 46: ...4 20 SUPERSERVER 6017R N3RF4 6017R N3RFT User s Manual Notes...
Page 85: ...Chapter 6 Advanced Chassis Setup 6 9 Figure 6 5 Removing Replacing the Power Supply 1 2...
Page 86: ...6 10 SUPERSERVER 6017R N3RF4 6017R N3RFT User s Manual Notes...
Page 120: ...A 2 SUPERSERVER 6017R N3RF4 6017R N3RFT User s Manual Notes...