ERVER 6014P-8/6014P-8R/6014P-82R/6014P-82 User's Manual
6-5
Power Supply
6014P-8R/6014P-82R
The SuperServer 6014P-8R/6014P-82R has a redundant 560 watt redundant
power supply configuration consisting of two hot-swappable power mod-
ules. Each power supply module has an auto-switching capability, which
enables it to automatically sense and operate with a 100V - 240V input
voltage.
Power Supply Failure
If either of the two power supply modules fail, the other module will take the
full load and allow the system to continue operation without interruption.
The Power On LED on the control panel will turn yellow and remain on until
the failed module has been replaced. Replacement modules can be ordered
directly from Supermicro (see contact information in the Preface). The
power supply modules have a hot-swap capability, meaning you can re-
place the failed module without powering down the system.
Removing/Replacing the Power Supply
You do not need to shut down the system to replace a power supply
module. The redundant feature will keep the system up and running while
you replace the failed hot-swap module. Replace with the same model -
SP562-1S (p/n PWS-0057), which can be ordered directly from Supermicro
(see Contact Information in the Preface).
1.
Removing the power supply
First unplug the power cord from the failed power supply module. To
remove the failed power module, first locate the colored release tab (1).
Push the tab to the right (2) and then pull the module straight out with the
handle provided (3) (Figure 6-5, single power supply server shown). The
power supply wiring was designed to detach automatically when the mod-
ule is pulled from the chassis.
2.
Installing a new power supply
Replace the failed hot-swap module with another SP562-1S power supply
module (p/n PWS-0057). Simply push the new power supply module into
the power bay until you hear a click. Finish by plugging the AC power cord
back into the module.
Summary of Contents for SUPERSERVER 6014P-8
Page 5: ...v Preface Notes...
Page 10: ...Notes x SUPERSERVER 6014P 8 6014P 8R 6014P 82R 6014P 82 User s Manual...
Page 25: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the System...
Page 30: ...3 4 SUPERSERVER 6014P 8 6014P 8R 6014P 82R 6014P 82 User s Manual Notes...
Page 60: ...5 26 SUPERSERVER 6014P 8 6014P 8R 6014P 82R 6014P 82 User s Manual Notes...
Page 73: ...Chapter 6 Advanced Chassis Setup 6 13 Figure 6 6 Reconfiguring the Power Supply Step 2 Step 1...
Page 74: ...6 14 SUPERSERVER 6014P 8 6014P 8R 6014P 82R 6014P 82 User s Manual Notes...
Page 91: ...Chapter 7 BIOS 7 17 P3V3 P5V P1V8 P2V5 HECETA_MEM_VTT PIVO_NIC N12V_Scaled P3V3_STBY...
Page 102: ...A 6 SUPERSERVER 6014P 8 6014P 8R 6014P 82R 6014P 82 User s Manual Notes...
Page 126: ...C 4 SUPERSERVER 6014P 8 6014P 8R 6014P 82R 6014P 82 User s Manual Notes...