ERVER 6014P-8/6014P-8R/6014P-82R/6014P-82 User's Manual
2-5
Checking the Serverboard Setup
After you install the 6014P-8/6014P-8R/6014P-82R/6014P-82 in the rack,
you will need to open the top cover to make sure the serverboard is prop-
erly installed and all the connections have been made.
1.
Accessing the inside of the System (see Figure 2-5)
First, release the retention screws that secure the system to the rack.
Grasp the two handles on either side and pull the system straight out until
it locks (you will hear a "click"). Next, depress the two buttons on the top
of the chassis to release the top cover (1). Push the cover away from you
(toward the rear of the chassis) until it stops (2). You can then lift the top
cover from the chassis to gain full access to the inside of the server.
To remove the system from the rack completely, depress the locking tabs in
the chassis rails (push the right-side tab down and the left-side tab up) to
continue to pull the system out past the locked position.
2.
Check the CPUs (processors)
Y o u s h o u l d h a v e o n e o r t w o p r o c e s s o r s a l r e a d y i n s t a l l e d i n t h e
serverboard. Each processor needs its own heatsink. See Chapter 5 for
instructions on processor and heatsink installation.
3.
Check the system memory
Your server system may have come with system memory already installed.
Make sure all DIMMs are fully seated in their slots. For details on adding
system memory, refer to Chapter 5.
4.
Installing add-on cards
If desired, you can install add-on cards to the system. See Chapter 5 for
details on installing PCI add-on cards.
5.
Check all cable connections and airflow
Make sure all power and data cables are properly connected and not block-
ing the chassis airflow. See Chapter 5 for details on cable connections.
Summary of Contents for SUPERSERVER 6014P-8
Page 5: ...v Preface Notes...
Page 10: ...Notes x SUPERSERVER 6014P 8 6014P 8R 6014P 82R 6014P 82 User s Manual...
Page 25: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the System...
Page 30: ...3 4 SUPERSERVER 6014P 8 6014P 8R 6014P 82R 6014P 82 User s Manual Notes...
Page 60: ...5 26 SUPERSERVER 6014P 8 6014P 8R 6014P 82R 6014P 82 User s Manual Notes...
Page 73: ...Chapter 6 Advanced Chassis Setup 6 13 Figure 6 6 Reconfiguring the Power Supply Step 2 Step 1...
Page 74: ...6 14 SUPERSERVER 6014P 8 6014P 8R 6014P 82R 6014P 82 User s Manual Notes...
Page 91: ...Chapter 7 BIOS 7 17 P3V3 P5V P1V8 P2V5 HECETA_MEM_VTT PIVO_NIC N12V_Scaled P3V3_STBY...
Page 102: ...A 6 SUPERSERVER 6014P 8 6014P 8R 6014P 82R 6014P 82 User s Manual Notes...
Page 126: ...C 4 SUPERSERVER 6014P 8 6014P 8R 6014P 82R 6014P 82 User s Manual Notes...