Chapter 6: Advanced Chassis Setup
6-10 Drive Bay Installation/Removal
Accessing the Drive Bays
SATA Drives: You do not need to access the inside of the chassis or remove power
to replace or swap SATA drives. Proceed to the next step for instructions. You must
use standard 1" high, SATA drives in the system.
Note:
Refer to the following FTP site for setup guidelines: <ftp://ftp.supermicro.com/
driver/SAS/LSI/LSI_SAS_EmbMRAID_SWUG.pdf> and Supermicro's web site for
additional inmformation <
http://www.supermicro.com/support/manuals/>.
The SC827 chassis contains four individual motherboards in separate node
drawers. Each motherboard node controls a set of three hard drives. Note that if a
motherboard node drawer is pulled out of the chassis, the hard drives associated
with that node will power down as well.
Figure 6-15. Hard Drives and the Corresponding Motherboards
6-15
1
A
1
B
1
C
1
D
Motherboard Drawer Locations in the Chassis
Motherboard B
Controls HDDs B1, B2 and B3
Motherboard D
Controls HDDs D1, D2 and D3
Motherboard A
Controls HDDs A1, A2 and A3
Motherboard C
Controls HDDs C1, C2 and C3