Chapter 5: Advanced Serverboard Setup
Infi niBand LED Indicators (2022TG-
HIBQRF only)
Two Infi niBand LED indicators (LE2/LE3)
are located near the Infi niBand port of the
H8DGT-HIBQF Serverboard. The green
LED (LE2) is the Infi niBand link LED while
the yellow LED (LE3) indicates activity.
Refer to the tables at the right for details.
5-19
UID LED (LE1)
A rear UID LED Indicator, located at LE1,
works in conjunction with the rear UID switch
to provide easy identifi cation for a unit that
might be in need of service. Refer to Page
2-13 for further UID details.
5-12 SATA Ports
SATA Ports
There are no jumpers to confi gure the SATA
ports, which are designated SATA0 through
SATA3. See the table on the right for pin
defi nitions.
SATA Port
Pin Defi
nitions
(I-SATA0~I-SATA5)
Pin # Defi nition
1
Ground
2
TXP
3
TXN
4
Ground
5
RXN
6
RXP
7
Ground
Infi niBand LED
(LE2) Activity
LED
Color
Status
Defi nition
Green
Solid
Infi niBand Connected
Off
Off
No Connection
Infi niBand LED
(LE3) Activity
LED
Color
Status
Defi nition
Yellow
Solid
Infi niBand Active
Yellow
Dim
Infi niBand
Connected, Activity
Idle
Off
Off
No Connection
Summary of Contents for A+ SERVER 2022TG-HIBQRF
Page 2: ...A SERVER 2022TG HTRF A SERVER 2022TG HIBQRF SUPER USER S MANUAL Revision 1 0 ...
Page 17: ...1 8 A SERVER 2022TG HTRF HIBQRF User s Manual Notes ...
Page 31: ...A SERVER 2022TG HTRF HIBQRF User s Manual Notes 3 4 ...
Page 61: ...A SERVER 2022TG HTRF HIBQRF User s Manual Notes 5 26 ...
Page 99: ...A SERVER 2022TG HTRF HIBQRF User s Manual Notes 7 18 ...
Page 101: ...A SERVER 2022TG HTRF HIBQRF User s Manual Notes A 2 ...