Chapter 2: Server Installation
2-9
2-6 Checking the Serverboard Setup
After you install the A+ Server 2122TG-H6IBQRF/H6RF in the rack, you will need
to open the unit to make sure the serverboard is properly installed and all the
connections have been made.
Before operating the SC217 chassis for the first time, it is important to remove the
protective film covering the top of the chassis, in order to allow for proper ventilation
and cooling.
Removing the Chassis Cover and Protective Film (Figure 2-7)
1. Uplug the AC power cord from any external power source.
2. Remove the two screws which secure the top cover onto the chassis as
shown above.
3. Lift the top cover up and off the chassis.
4.
Peel off the protective film covering the top cover and the top of the chassis
5. Check that all ventilation openings on the top cover and the top of the chassis
are clear and unobstructed.
Replace the chassis cover and reconnect the AC power cord.
Figure 2-7. Accessing the Inside of the System
Remove two screws
Check Ventilation
Openings
1
2
1
3
1
4
1
1
Caution:
Except for short periods of time, do not operate the server without the
cover in place. The chassis cover must be in place to allow proper airflow and
prevent overheating.
Summary of Contents for A+ 122TG-H6IBQRF
Page 1: ... SUPER USER S MANUAL Revision 1 0c A SERVER 2122TG H6IBQRF 2122TG H6RF ...
Page 16: ...1 8 A SERVER 2122TG H6IBQRF H6RF USER S MANUAL Notes ...
Page 30: ...A SERVER 2122TG H6IBQRF H6RF USER S MANUAL 3 4 Notes ...
Page 50: ...4 20 A SERVER 2122TG H6IBQRF H6RF USER S MANUAL Notes ...
Page 96: ...6 20 A SERVER 2122TG H6IBQRF H6RF USER S MANUAL Notes ...
Page 114: ...A 2 A SERVER 2122TG H6IBQRF H6RF USER S MANUAL Notes ...