Chapter 2: Server Installation
2-5
Installing the Outer Rails
Installing the Outer Rails to the Rack
Measure the distance from the front rail to the rear rail of the rack.
1.
Attach a short bracket to the front side of the right outer rail and a long
2.
bracket to the rear side of the right outer rail.
Adjust both the short and long brackets to the proper distance so that the rail
3.
can fi t snugly into the rack.
Secure the short bracket to the front side of the outer rail with two M4 screws
4.
and the long bracket to the rear side of the outer rail with three M4 screws.
Repeat these steps for the left outer rail.
5.
Locking Tabs
Both chassis rails have a locking tab, which serves two functions. The fi rst is to
lock the server into place when installed and pushed fully into the rack, which is
its normal position. Secondly, these tabs also lock the server in place when fully
extended from the rack. This prevents the server from coming completely out of the
rack when you pull it out for servicing.
Figure 2-2. Installing the Rack Rails
Summary of Contents for 6016T-6RFT
Page 1: ...SUPERSERVER 6016T 6RFT SUPERSERVER 6016T 6RF SUPER USER S MANUAL 1 0 ...
Page 5: ...v Preface Notes ...
Page 21: ...Chapter 2 Server Installation 2 7 Figure 2 3 Installing the Server into a Rack ...
Page 23: ...Chapter 2 Server Installation 2 9 Figure 2 4 Accessing the Inside of the System ...
Page 28: ...3 4 SUPERSERVER 6016T 6RFT 6016T 6RF User s Manual Notes ...
Page 71: ...Chapter 6 Advanced Chassis Setup 6 9 Figure 6 5 Removing Replacing the Power Supply 1 2 ...
Page 72: ...6 10 SUPERSERVER 6016T 6RFT 6016T 6RF User s Manual Notes ...
Page 102: ...7 30 SUPERSERVER 6016T 6RFT 6016T 6RF User s Manual Notes ...
Page 104: ...A 2 SUPERSERVER 6016T 6RFT 6016T 6RF User s Manual Notes ...